摘要
介绍了白马循环流化床示范电站有限公司循环流化床(CFB)锅炉的双支腿结构特点及锅炉在调试过程中出现的床料翻床现象,分析了床料翻床的原因,并提出了行之有效的解决办法,其运行经验值得国内同型机组借鉴。
The features of dual support- leg structure for circulating fluidized bed (CFB) boiler in Baima CFB Exemplary Power Plant Co Ltd, as well as the turning - over phenomenon of bed - material in debugging process of said boiler have been presented. The caues leading to turning- over of bed- material being analysed, and effective solving measures being put forward. The experience in operation of said boiler is worth to be used for reference to other similar units in our country.
出处
《热力发电》
CAS
北大核心
2007年第6期127-129,共3页
Thermal Power Generation
关键词
循环流化床锅炉
双支腿
床料
翻床
运行调整
CFB boiler
dual support - leg
bed - material
"turning - over"
combustion adjustment