摘要
根据现场实测数据,确定韶钢90 tCONSTEEL电弧炉的非线性电抗模型和电气圆图,从而制定了较合理的供电曲线.文中着重讨论了建立电弧炉电抗模型的原则、方法及其对制定合理供电曲线的作用.
A non-linear reactance model and an electric principle diagram of power supply for the 90tCONSTEEL EAF at SISG are constructed, based on the data on-site gathered with the furnace, and thus a more rational power supply curve is worked out. The principles and methods of the EAF reactance model, and their effects on formulating a rational power supply curve are described in the paper.
出处
《南方金属》
CAS
2007年第4期11-13,共3页
Southern Metals
关键词
电弧炉
电抗模型
供电
EAF
reactance model
power supply