摘要
阐述了对焦炉煤气中苯并(a)芘含量提取处理方法中的索氏法和超声法的两种方法,分析了两种方法测定相同含浓度苯并(a)芘含量样品测试数据差异及产生原因,用实验数据分析说明了使用超声法作为测定焦炉煤气中苯并(a)芘含量是一种最佳的处理方法。
Suo's method and ultrasonic method for extracting B(a)P (Benzo(a)Pyrene) content from coke oven gas were introduced. The two methods were used to test the samples containing same density of B (a)P. Differences of the testing data and causes produced were analyzed. The testing results showed that the ultrasonic method was the best method to test B (a)P content in coke oven gas.