期刊文献+

种植体支持对KennedyⅠ类可摘局部义齿应力分布的影响 被引量:4

Influence of Implant-supporting on the Stress Distribution of Kennedy Class I Removable Partial Denture
下载PDF
导出
摘要 目的:分析增加种植体支持对于KennedyⅠ类缺失可摘局部义齿应力分布影响。方法:应用三维有限元法,在不同加载条件下分析比较有无种植体支持对于双侧后牙游离缺失可摘局部义齿应力分布的影响。结果:增加种植体支持可以显著降低可摘局部义齿基托的位移,减小义齿基牙牙周膜和基托下支持组织的应力。结论:由种植体支持的可摘局部义齿有利于保护义齿基牙及基托下支持组织的健康。 Objective: To make a comparative study on tress distribution between implant -supported removable partial denture and traditional removable partial denture. Methods: 3 - D FEM was used to make a comparative study of the effects of the implant to stress distribution of removable partial denture under different loads. Results: The application of implant can lower the displacement of the base and decrease the stress of abutments and residual ridge. Conclusion: The application of implant can be helpful to protect the abutments and residual ridge.
作者 贾洪宇 施斌
出处 《口腔医学研究》 CAS CSCD 2007年第3期293-296,共4页 Journal of Oral Science Research
关键词 RPD 种植体 基牙 三维有限元 RPD Implant Abutment 3 -D FEM
  • 相关文献

参考文献10

  • 1Giffin KM.Solving the distal extension removable partial denture base movement dilemma:A clinical report[J].J Prosthet Dent,1996,76(4):347-349.
  • 2Mitrani R,Brudvik JS,Phillips KM.Posterior implants for distal extension removable prostheses:A retrospective study[J].Int J Periodontics Restorative Dent,2003,23(4):353-359.
  • 3Kuzmanovic DV,Payne AG,Purton DG,et al.Distal implants to modify the Kennedy classification of a removable partial denture:A clinical report[J].J Prosthet Dent,2004,92(1):8-11.
  • 4李玲,薛淼,张富强,张睿,于力牛,王成焘.上下颌骨及牙列三维有限元模型的建立[J].口腔材料器械杂志,2003,12(3):117-120. 被引量:14
  • 5Ishigaki S,Nakano T,Yamada S,et al.Biomechanical stress in bone surrounding an implant under simulated chewing[J].Clin Oral Impl Res,2003,14:97-102.
  • 6Halterman SM,Rivers JA,Keith JD,et al.Implant support for removable partial overdentures:A case report[J].Implant Dent,1999,8(1):74-78.
  • 7舒克里,程祥荣,张倩.Ⅰ形杆卡应力分布的三维有限元法分析[J].口腔医学研究,2003,19(3):199-201. 被引量:4
  • 8宋文植,尹万忠.设置缓冲间隙对下颌种植覆盖总义齿应力分布的影响[J].中华口腔医学杂志,2000,35(4):263-265. 被引量:22
  • 9Mellal A,Wiskott HW,Botsis J,et al.Stimulating effect of implant loading on surrounding bone-comparison of three numerical models and validation by in vivi data[J].Clin.Oral Impl.Res,2004,15(2):239-248.
  • 10张颖,白乐康,李建华,王宇春.下颌桩核基牙式全口覆盖义齿基牙牙周支持组织的应力分析[J].实用口腔医学杂志,2004,20(4):469-471. 被引量:1

二级参考文献30

  • 1徐剑青,由敬舜.切牙牙体,牙周膜的应力分析及其临床意义[J].中华口腔医学杂志,1993,28(1):53-55. 被引量:5
  • 2朱希涛 周书敏.完全固定桥基牙及其支持组织的光测应力分析[J].北京医学院学报,1983,15:293-293.
  • 3周书敏 朱希涛 等.牙周支持组织三维光弹性应力分析[J].中华口腔医学杂志,1987,22(6):313-316.
  • 4周书敏 吴仲谋.应用有限单元法对下颌磨牙不同高度的牙周支持组织的应力分析[J].北京医学院学报,1984,16(4):293-293.
  • 5Farah JW,Craig RG. Finite element stress analysis of restored axisymmetric first molar. J Dent Res , 1974,53 (4):859
  • 6Atmaram GH, Mohammed H. Estimation of physiologic stresses with a natural tooth considering fibrons PDL strucrure. J Dent Res, 1981,60(5):873
  • 7Sato Y ,Tsuga K, Abe Y, et al. Dimensional measurement and finite element analysis of I - bar clasps in clinical use. J of Rehabil,2000,27(1): 935-939.
  • 8Demer WJ. An analysis of mesial rest I - bar clasp design. J Prosthetic Dent,1976,36(3) : 243 -253.
  • 9Krol AJ. Clasp design for extension base removable partial denture,J prosthetic Dent, 1973,29 ( 4 ) : 408 - 415.
  • 10Naik PR, Duncanson MG Jr, Mitchell DL, et al. Evaluation of stress and forces in selected I - bar using the finite element method. Journal of Prosthedont, 1997,6 ( 1 ) : 43 - 54.

共引文献36

同被引文献29

  • 1贾洪宇,施斌.不同加载条件下RPI卡环固位可摘局部义齿的三维有限元分析[J].口腔医学研究,2006,22(3):273-276. 被引量:6
  • 2Fueki K, Kimoto K, Ogawa T, et al. Effect of implant-supported or retained dentures on masticatory performance: A systematic review [J]. J Prosthet Dent, 2007, 98 (6) :470 - 477.
  • 3Abu-Saleh T, Marnewick J. Implant-supported crowns for a shortened dental arch: A case report [ J]. J Contemp Dent Praet, 2008, 9(5):114- 121.
  • 4Mengel R, Kreuzer G, Lehmann KM, et al. A telescopic crown concept for the restoration of partially edentulous patients with aggressive generalized periodontitis: A 3-year prospective longitudinal study[J].Int J Period Restor Dent, 2007, 27(3) :231-239.
  • 5Turkyilmaz I. Use of distal implants to support and increase retention of a removable partial denture : A case report [ J ]. J Can Dent Assoc, 2009, 75(9) :655 -658.
  • 6Ohkubo C, Kurihara D, Shimpo H, et al. Effect of implant support on distal extension removable partial dentures: In vitro assessment[J]. J Oral Rehabil, 2007, 34( 1 ) : 52 - 56.
  • 7Kuzmanovic DV, Payne AG, Purton DG. Distal implants to modify the Kennedy classification of a removable partial denture: A clinical report[J]. J Prosthet Dent, 2004, 92( 1 ) : 8 -11.
  • 8Cunha LD, Pellizzer EP, Verri FR, Pereira JA. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures [J]. Implant Dent, 2008, 17(3) : 278 -287.
  • 9Matsushita Y, Kitoh M, Mizuta K, et al. Two- dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution[J]. J Oral Implantol, 1990, 16( 1 ) : 6 -ll.
  • 10Kong L, Gu Z, Li T, et al. Biomechanical optimization of implant diameter and length for immediate loading: A non-linear finite element analysis [J]. Int J Prosthodont, 2009, 22(6) : 607 -615.