期刊文献+

余热锅炉热交换管破裂原因分析

FRACTURE ANALYSIS OF THE PIPES FOR EXCHANGING BOILER'S SURPLUS HEAT
下载PDF
导出
摘要 采用化学成分、显微组织、裂纹及断口特征等方法对余热锅炉热交换管破裂原因进行了分析。结果表明,热交换管破裂是烟道气流对管道的腐蚀和冲蚀磨损的结果。建议采用具有抗蚀能力的高温材料并控制烟道气硫和氧的含量。 In this paper, the failure reason of the pipes transporting boiler's surplus heat are analyzed. After a comprehensive study on chemical composition, microsturcture, fractures and cracks, the results show that the fractures oceured under the effects of combined freting and erosion of the airflow from the flue, it is suggested to use steel with high temperature strength and high anti-erosion, at the same time, strictly controlling the content of sulfur and oxygen in the flue is necessary.
出处 《理化检验(物理分册)》 CAS 2007年第3期144-146,162,共4页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
基金 广东省自然科学基金资助项目(04300026) 华南理工大学自然科学基金资助项目(200532)
关键词 失效分析 热交换 腐蚀 Failure analysis Heat exchanging Erosion
  • 相关文献

参考文献3

  • 1GB 3077--1978合金结构钢号及化学成分[s].
  • 2刘正义,吴连生,许麟康,等.机械装备失效分析图谱[M].广州:广东科技出版社,1990.
  • 3周永欣,吕振林,张敏,唐文亭,赵西城.30CrMo钢泵体开裂失效分析[J].机械工程材料,2004,28(9):52-54. 被引量:5