期刊文献+

单扫描示波极谱法测定非那雄胺 被引量:2

Determination of Finasteride by Single-Sweeping Oscillopolarography
下载PDF
导出
摘要 在0.01 mol·L^-1 HCl-2.5×10^-5mol·L^-1十二烷基三甲基氯化铵-水-乙醇溶液(21+4)底液中,采用单扫描示波极谱法测定,非那雄胺在-1.27 V(vs.SCE)处有一灵敏的极谱还原波。二阶导数峰电流I″p与非那雄胺浓度在1.0~10.0 mg.L-1范围内呈线性关系,相关系数为0.999 6(n=6),检出限为0.2 mg·L^-1。连续11次平行测定2.0 mg·L^-1非那雄胺还原波峰电流,相对标准偏差为1.3%。此方法用于片剂中非那雄胺含量的测定,其回收率在99.7%~105.2%之间。 In a mixed base solution of 0. 01 mol · L^-1 HCl and 2. 5 × 10^-5 mol · L^-1 dodecyl-trimethyl ammonium chloride in aqueous ethanol solution (H2O+C2H5OH= 21 +4), a sensitive reduction wave was given by finasteride with its peak potential at -1. 27 V (vs. SCE) by single sweeping oscillopolarography. Linear relationship between the 2nd derivative of peak current (I″p) of the reduction wave and the concentration of finasteride was obtained in the range of 1.0-10. 0 mg of finasteride per L of solution (r= 0. 999 6), with a detection limit of 0. 2 rng · L^-1. The RSD's found when tested at the concentration level of 2. 0 mg ·L^-1 was 1.3% (n=11). The proposed method has been applied to the analysis of finasteride tablet samples, giving recoveries in the range of 99. 7%-105. 2%.
作者 徐敏 宋俊峰
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2007年第3期201-203,206,共4页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金 陕西省自然科学基金资助项目(No.2002B01)
关键词 单扫描示波极谱法 非那雄胺 十二烷基三甲基氯化铵 Single sweeping oscillopolarography Finasteride Eodecyl-trimethyl ammonium chloride
  • 相关文献

参考文献10

  • 1Ekman P.A risk-benefit assessment of treatment with finasteride in benign prostatic hyperplasia[J].Drug Sar,1998,18(3):161.
  • 2Takano T,Hata S.High-performance liquid chromatographic determination of finasteride in human plasma using direct injection with column switching[J].J Chromatogr B:Biomed Sci Appl,1996,676(1):141.5
  • 3Carlin J R,Christofalo P,Vandenheuvel W J A.High-performance liquid chromatographic determination of N-(2-methyl-2-propyl)-3-oxo-4-aza-5α-androst-1-ene-17β-carboxamide,a 4-azasteroid,in human plasma from a phase I study[J].J Chromatogr,1988,427(1):79.
  • 4Matuszewski B K,Bayne W F.Fluorogenic reaction between adenine derivatives and chloroacetaldehyde and its application to the determination of 9-(2-chloro6-fluorobenzyl) adenine in human plasma[J].Anal Chim Acta,1989,227(1):189.
  • 5Ptacek P,Macek J,Klima J.Determination of finasteride in human plasma by liquid-liquid extraction and high-performance liquid chromatography[J].J Chromatogr B:Biomed Sci Appl,2000,738(2):305.
  • 6Ryan J A,Compton S V,Brooks M A,et al.Rapid verification of identity and content of drug formulations using mid-infrared spectroscopy[J].J Pharm Biomed Anal,1991,9(4):303.
  • 7Amer S M.Polarographic behavior and determination of finasteride[J].Ⅱ Farmaco,2003,58:159.
  • 8蒲宇宏,张月霞.铋(Ⅲ)-8-羟基喹哪啶体系极谱行为——表面活性剂增敏机理和分析应用——Ⅱ.铋(Ⅲ)-8-羟基喹哪啶络合物电极反应和十二烷基苯磺酸钠增敏机理[J].分析化学,1993,21(3):285-289. 被引量:5
  • 9De Boer H S,Van Oort W J,Zuman P.Polarographic analysis for corticosteroid Part 6.Mechanism of polargraphic electroreduction of some △4-3-ketosteroids and△1,4 3-ketosteroids[J].Anal Chim Acta,1981,130(98):111.
  • 10Laviron E.Adsorption,autoinhibition and autocatalysis in polarography and in linear potential sweep voltammetry[J].J Electronal Chem,1974,52(3):355.

二级参考文献7

共引文献4

同被引文献565

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...