摘要
在0.01 mol·L^-1 HCl-2.5×10^-5mol·L^-1十二烷基三甲基氯化铵-水-乙醇溶液(21+4)底液中,采用单扫描示波极谱法测定,非那雄胺在-1.27 V(vs.SCE)处有一灵敏的极谱还原波。二阶导数峰电流I″p与非那雄胺浓度在1.0~10.0 mg.L-1范围内呈线性关系,相关系数为0.999 6(n=6),检出限为0.2 mg·L^-1。连续11次平行测定2.0 mg·L^-1非那雄胺还原波峰电流,相对标准偏差为1.3%。此方法用于片剂中非那雄胺含量的测定,其回收率在99.7%~105.2%之间。
In a mixed base solution of 0. 01 mol · L^-1 HCl and 2. 5 × 10^-5 mol · L^-1 dodecyl-trimethyl ammonium chloride in aqueous ethanol solution (H2O+C2H5OH= 21 +4), a sensitive reduction wave was given by finasteride with its peak potential at -1. 27 V (vs. SCE) by single sweeping oscillopolarography. Linear relationship between the 2nd derivative of peak current (I″p) of the reduction wave and the concentration of finasteride was obtained in the range of 1.0-10. 0 mg of finasteride per L of solution (r= 0. 999 6), with a detection limit of 0. 2 rng · L^-1. The RSD's found when tested at the concentration level of 2. 0 mg ·L^-1 was 1.3% (n=11). The proposed method has been applied to the analysis of finasteride tablet samples, giving recoveries in the range of 99. 7%-105. 2%.
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2007年第3期201-203,206,共4页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金
陕西省自然科学基金资助项目(No.2002B01)
关键词
单扫描示波极谱法
非那雄胺
十二烷基三甲基氯化铵
Single sweeping oscillopolarography
Finasteride
Eodecyl-trimethyl ammonium chloride