期刊文献+

电站轴流风机喘振的危害及预防措施 被引量:7

Harmful Surging of Axial Blowers in Power Plants and Measures of Protection
下载PDF
导出
摘要 锅炉高负荷时,轴流引风机和送风机常发生喘振,影响锅炉安全运行。嘉兴发电有限责任公司对空气预热器进行密封改造,减少了漏风,解决了引风机的喘振;又对送风系统的阻力和调节方法进行改进,解决了送风机的喘振。运行情况证明这些改进是有效的。 Surging often occur to axial flow, forced and induced, draft fans at high boiler outputs, endangering the boiler's safety of operation. Jiaxing Power Co. Ltd has solved the surging problem of its induced-draft fan by reconstructing the sealing of the air preheater, reducing its air leakage;while that of the forced-draft fan was solved, by reducing the flow resistence of the air feeding system, and improving way of controlling. Operational results have proven the effectiveness of all these improvements.
作者 童红政 吴伟
出处 《发电设备》 2007年第4期292-293,共2页 Power Equipment
关键词 能源与动力工程 发电厂 轴流风机 喘振 预防措施 energy and power engineering power plant axial fan surging protective measure
  • 相关文献

参考文献1

  • 1王文飙.泵与风机[M].北京:水利出版社,1982.

同被引文献42

引证文献7

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部