期刊文献+

大型氢冷发电机定子线棒漏氢修复后的试验 被引量:1

Check-tests After Leakage Repair of a Large Hydrogen Cooled Generator Stator's Winding
下载PDF
导出
摘要 通过一台1000 MW大型氢冷发电机定子线棒端部漏氢修复后的试验实例,总结了验证修复效果的各项试验准备、实施、数据分析及注意事项,提出了一些新颖、实用的试验手段。 Besed on the experience, gained of repairing hydrogen leakage defects of stator winding, of a large 1 000 MW hydrogen cooled generator, the procedure of check-testing the outcome of the repair work is being summarized, including preparations required, tests to be performed, and data analysis, accompanied by points to be observed. Some of the mentioned means of testing are inventive and practical.
作者 王建涛 关高
出处 《发电设备》 2007年第4期312-315,共4页 Power Equipment
关键词 能源与动力工程 发电机 定子线棒 漏氢 试验 energy and power engineering generator stator conductor bar hydrogen leakage testing
  • 相关文献

参考文献2

  • 1J Allison. Revision of generator stator water pressure testing procedure[Z]. 2002.
  • 2JB/T6228-1992,汽轮发电机绕组内部水系统检验方法及评定[S].

同被引文献2

  • 1Joon Soo Kirn, Young Jak Roh, Hee Sig Shin. Hydrogen to Stator Cooling Water System Leaks Due To Wormholes[C]//. Proceedings of 2000 International Joint Power Generation Conference, Miami Beach, Florida, July 23-26, 2000.
  • 2Joseph A. Worden Jorge M. Mundulas Understanding, Diagnosing, and Repairing Leaks in Water-Cooled Generator Stator Windings[R].GE, 2001.