摘要
针对本钢4#高炉意外爆震的事故,介绍了高炉炉顶水冷站的工作原理;对产生爆震的原因进行了详细的分析,根据现场实际情况对事故进行了应急处理;总结了事故的经验教训,以供在今后的生产实践中借鉴.
Based on the accident of boiler explosion at BENGANG, this paper introduces the operation of cooling station on the top of boiler; provides detailed analysis for the causes to the accident and reactions and measurements at the site of the accident;and draws lessons from the accident for the future practice.
出处
《沈阳工程学院学报(自然科学版)》
2007年第3期237-238,253,共3页
Journal of Shenyang Institute of Engineering:Natural Science
关键词
水冷站
液位
阀门
泄漏
自动控制
cooling station, fluid position, valve, leakage, automatic control