期刊文献+

宝钢交联电力电缆变频谐振耐压试验的应用 被引量:1

Application of Variable Frequency Resonance Withstand Voltage Test to XLPE Power Cable for Baosteel
下载PDF
导出
摘要 对XLPE交联聚乙烯电力电缆的耐压试验方法作了总结,并根据宝钢电力电缆安装后现场试验的做法和问题,结合国内外现行的不同标准,论述了变频谐振试验在宝钢交联电力电缆的应用效果,给出了进一步研究的建议。 The current withstand vohage test methods to XLPE power cable in detail was summarized. Meanwhile, according to the operating method and the existing problems of the Baosteel XLPE power cable on-site withstand voltage test, and combining the current dissimilar standards both at home and abroad, it clarified the application effects of the variable frequency resonance test to XLPE power cable. Furthermore, some advices for the follow-up researches of the variable frequency resonance test in future were put forward.
作者 钱峰 胡宝年
出处 《冶金动力》 2007年第3期3-5,共3页 Metallurgical Power
关键词 电力电缆 耐压试验 变频谐振 应用 power cable withstand voltage test variable frequency resonance application
  • 相关文献

参考文献2

  • 1IEC60840. Power cable with extruded insulation and their acces sories for rated voltage above 30 kV (U.=36 kV) up to 150 kV (Um=170 kV) -Test methods and requirements[S]. 2004.
  • 2IEC62067. Power cable with extruded insulation and their acees sories for rated voltage above 150 kV (Um=I70 kV) up to 500 kV (Um=550 kV) -Test methods and requirements[S]. 2001.

同被引文献8

  • 1陈雄宾.谐振耐压试验中电晕对品质因数的影响[J].电力建设,2006,27(3):30-32. 被引量:4
  • 2葛延津,钱晓龙.电力电子技术[M].沈阳:东北大学出版社,2002:238-240.
  • 3蒋英圣.简论用变频谐振装置进行GIS现场试验的等价性.高压电器,1988,(5):52-56.
  • 4GB/T 16927.1-1997高电压试验技术第一部分:一般试验要求[S].北京:中国标准出版社,1997.
  • 5张仁豫,陈昌渔,王昌长.高电压实验技术[M].2版.北京:清华大学出版社,2003.
  • 6黄慕义.电网络理论[M].武汉:华中理工大学出版社,1991.
  • 7陈道炼.DC-AC逆变技术及应用[M].北京:机械工业出版社,2003.
  • 8IEC60840.Power cable with extruded insulation and their access sories for rated voltage above 30 kV up to 150 kV-Teat methods and requirements[S],2004.