期刊文献+

应力调控型带锁髓内钉治疗股骨骨折的应力水平研究 被引量:2

Treatment of femoral fractures with stress-controlled auto-compression locking nails
原文传递
导出
摘要 目的探讨应力调控型带锁髓内钉(SCALN)治疗股骨骨折后应力水平的变化。方法采集12具成人新鲜尸体股骨标本,模拟Panjabi方法制作股骨中段横断骨折模型,将标本分为三组(每组3个标本),分别采用SCALN、第一代自动加压带锁髓内钉(ALN)和普通带锁髓内钉(GK钉)固定,均进行系统生物力学性能测试、应力遮挡分析和应力水平测量,并进行比较。结果与ALN、GK钉相比,SCALN应力-应变关系值分别小14%和18%(P〈0.05);应力遮挡率分别小10%和66%(P〈0.05)。SCALN刚柔结合弹性动态固定使股骨断端应力水平接近生理性,且手术操作方便。结论SCALN在有效控制骨折端弯、扭、剪、旋有害应力的同时,解决了临床上坚强内固定骨折断端无应力传导的问题,是当前新一代股骨骨折优良的髓内固定器械。 Objective To study the stress changes at the fracture ends in treatment of femoral fractures with stress-controlled auto-compression locking nails (SCALN) . Methods Twelve femoral specimens from fresh adult cadavers were collected. The transverse femoral fracture models were created in the specimens by Panjabi method and randomized into 3 groups which were fixated with SCALN, ALN (auto-compression locking nail) and GK(Gross-Kempf) After fixation, tests of biological mechanics, stress-shielding analysis and t of stresses were performed systemically. Results were compared among the 3 groups. Results Compared with ALN and GK nails, the strain-stress ratio of SCALN was 14% and 18% smaller respectively, and the stress-shielding rate of SCALN 10% and 66% smaller respectively( P 〈 0.05) . Under SCALN fixation, the stress at the femoral fracture ends approximated the normal level. Conclusion SCALN is a good intramedullary fixator for femoral fractures, because on the one hand it can effectively control such harmful stresses as bending, twisting, shearing and rotating, and on the other hand it can maintain normal stress conduction at the fracture ends under firm internal fixation.
出处 《中华创伤骨科杂志》 CAS CSCD 2007年第7期670-674,共5页 Chinese Journal of Orthopaedic Trauma
基金 河南省杰出人才创新基金项目(0621002400)
关键词 骨钉 股骨骨折 骨折固定术 髓内 生物力学 Bone nails Femoral fracture Fracture fixation, intramedullary Biomeehanies
  • 相关文献

参考文献3

二级参考文献21

  • 1许纬洲,王以进,杜靖远,贺长清,郑毅,王玉记.自控微动带锁髓内钉内固定对骨折愈合影响的生物力学实验研究[J].医用生物力学,2003,18(4):206-212. 被引量:12
  • 2Wallace AL,Draper ERC,Strachen ID. The vascular response to micromovement in experimental fracture micromovement in orthopaedics. 1st eds. London: university of oxford, 1992. 40-44.
  • 3Sarmiento A,Mckellop HA,Llinas A. Effect of loading and fracture motions on diaphyseal tibial fracture. J Orthop Res,1996,14:80-84.
  • 4Perre SM. The biomechanics and biology of internal fixation using plates and nails. Orthopedics,1989, 12:21-24.
  • 5Burstein AH. Musculoskeletal biomechanics in Evarts CM(ed). Surgery of the musculoskeletal system. Vo1. 1.New York: Chuvchill Livingstone, 1988. 251-286.
  • 6许纬洲 .发明专利公开说明书 .知识产权出版社 . A61B 17/72.
  • 7Winquist RA,Hansen ST Jr, Clawson DK. Closed intramedullary nailing of femoral fractures: a report of five hundred and twenty cases. J Bone Joint Surg(Am),1984,66:529-539.
  • 8Klemm KW,Borner M. Interlocking nailing of complex fractures of the femur and tibia. Clin Orthop,1986, (212):89-100.
  • 9Utvag SE, Korsnes L, Rindal DB, Reikeras O. Influence of flexible nailing in the later phase of fracture healing:strength and mineralization in rat femora. J Orthop Sci, 2001,6:576-584.
  • 10Klein P, Schell H, Streitparth F. The initial phase of fracture healing is specifically sensitive to mechanical conditions. J Orthop Res,2003,21:662-669.

共引文献13

同被引文献42

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部