摘要
以某地下工程为例,详细地介绍了无缝结构技术方案及技术措施细则,探讨了混凝土的浇筑细则,通过对施工效果的分析,得出了该技术防渗、抗裂,具有较高的可靠性的结论,对混凝土结构的开裂及防水问题有一定的指导意义。
Taking one underground structure works as example the technical scheme and measures for jointless construction are introduced. Detailed introduction is made on concrete construction. Construction effect analysis shows this technique is reliable in crack resistance and seepage control, which provide good references for similar works.
出处
《山西建筑》
2007年第21期78-79,共2页
Shanxi Architecture
关键词
地下混凝土结构
裂缝控制
膨胀加强带
underground concrete structure, crack control, expansive reinforce concrete tape