摘要
通过对OGFC路面降雨条件下地表径流和渗流的分析,提出了OGFC混合料排水设计指标的要求,结合江西婺源某高速公路OGFC混合料设计和施工实践,探讨了OGFC混合料设计和施工检测方法,为OGFC的合理设计与施工评价提供了参考和思路。
It is put forward the drainage requirement of OGFC mix design index with analysing the surface water flowage and seepage of OGFC pavement when rains. Combined with the OGFC mix design and construction practice of expressway Wuyuan Jiangxi, it is argued the method of OGFC mix design and construction test,providing reference and clue for reasonable design and construction evaluation of OGFC.
出处
《山西建筑》
2007年第21期177-178,共2页
Shanxi Architecture
关键词
OGFC混合料设计
地表径流
渗流
渗透系数
施工检测
OGFC mix design, surface water flowage, seepage, permeability coefficient, construction test