期刊文献+

NucliSens HIV-1QT和Amplicor HIV-1 monitor 1.5方法测定HIV-1病毒载量的比较研究 被引量:3

Comparison of NucliSens HIV-1 QT and Amplicor HIV-1 monitor 1.5 in detecting HIV-1 viral load
原文传递
导出
摘要 目的进行NuchSens HIV-1 QT和Amplicor HIV-1 monitor 1.5检测相同临床样品HIV-1病毒载量值之间的比较研究。方法收集临床样本82份,使用两种方法测定病毒载量,对病毒载量值进行统计分析。结果未测到核酸的和两种方法病毒载量对数值之差小于0.5的占88.9%;用△log10 VL〈0.5的56份样本统计两种方法的相关性,相关系数为0.956。结论NucliSens HIV-1 QT和Amphcor HIV-1 monitor 1.5两种方法测定的HIV病毒载量值有很好的相关性。 Objective To compare the results of detecting HIV-1 load by using NucliSens HIV-1 QT and Amplicor HIV-1 monitor 1.5 assays. Methods Eighty-two clinical samples were collected and HIV viral load was determined with the above-mentioned two methods. Results The number of samples in which values obtained by "NucliSens HIV-1 QT and Amplicor HIV-1 monitor 1.5 differed by 〈 0.5 log10 RNA copies/ml and in which the viral load was undetectable accounted for 88.9% methods was 0.956 in 56 samples of ,△log10 EL 〈 0 with the two methods are highly comparable. of the measures. The correlation coefficient between the two 5. Conclusion The results of HIV-1 viral load determination with the two methods are highly comparable.
出处 《中华实验和临床病毒学杂志》 CAS CSCD 北大核心 2007年第2期177-179,共3页 Chinese Journal of Experimental and Clinical Virology
基金 克林顿基金中国艾滋病卫国际双便函项目资助(2004)649
关键词 HIV-1 病毒载量 逆转录聚合酶链反应 核酸扩增技术 HIV-1 Viral load Reverse transcriptase polymerase chain reaction Nucleic acid amplification techniques
  • 相关文献

参考文献4

  • 1Reverts H, Marissens D, De Wit S, et al. Comparative evaluation of NASBA HIV-1 RNA QT, Amplicor HIV Monitor, and Quantiplex HIV RNA Assay, three methods for quantification of Human Immunodeficiency virus type 1 RNA in plasma. J Clin Microbial, 1996,34: 1058-1064.
  • 2Murphy DG, Cote L, Fauvel M, et al. Multicenter comparison of Roche COBAS AMPLICOR MONITOR version1. 5, Organon Teknika NucliSens QT with extractor, and Bayer Quantiplex Version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma. J Clin Microbiol, 2000,38: 4034-4041.
  • 3Dyer JR, Pileher CD, Shepard R, et al. Comparison of NueliSens and Roche Monitor assays for quantitation of levels of human immunodefieieney virus type 1 RNA in plasma. J Clin Microbiol, 1999,37 : 447-449.
  • 4Gottesman BS, Grosman Z, Lorber M, et al. Measurement of HIV RNA in patients infected by subtype C by assays optimized for subtype B results in an underestimation of the viral load. J Med Viral, 2004, 73: 167-171.

同被引文献31

  • 1张贺秋,李少波,刘劭钢,王国华,陈坤,宋晓国,冯晓燕.血清转换样本丙型肝炎病毒核酸、核心抗原及抗体检测对比研究[J].中国输血杂志,2006,19(3):177-180. 被引量:8
  • 2潘品良,许文燕,张麒,陶晓霞,毛玮,佐合拉,孙显光,秦光明,蒋岩.集合HIV RNA RT-PCR方法验证及其在IDUs中窗口期检测的应用[J].中国艾滋病性病,2007,13(3):198-200. 被引量:22
  • 3Eric Q Konnick, Sheri M Williams, Edward R Ashwood, et al. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan Analyre-Specific Reagent Assay and Comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 Assays[ J ]. Journal of Clinical Microbiology, 2005,43 (5) : 2133 - 2140.
  • 4Doris B. Strader, Teresa Wright, David L Thomas, et al. Diagnosis, Management, and Treatment of Hepatitis C[ J ]. Hepatology, 2004,39 (4) :1147- 1171.
  • 5Mellors JW, Munoz A, Giorgi JV, et al. Plasma viral load and CD+ lymphocytes as prognostic markers of HIV 1 infection[J]. Ann Intern Med 1997,126:946--954.
  • 6Mellors JW, Rinaldo CR, Jr Gupta P, et al. Prognosis in HIV-1 infection predicted by the quantity of virus in plasma[J]. Science 1996,272:1167--1170.
  • 7Raboud JM, Montaner JS, Conway B, et al. Suppression of plas ma viral load below 20 copies/mL is required to achieve a lonterm response to therapy[J]. AIDS 1998,12 : 1619-- 1624.
  • 8Carton JA, Maradona JA, de Ona M, et aL The prognostic value of cytomegalovirus antigenemia and viremia for t:he development of cytomegalovirus disease and the survival o AIDS patients[J]. Med Clin (Barc) 1999,113:205--209.
  • 9Resino Garcia S, Alonso Arias R, Jimenez Fuentes JL, et al. Vi- ral load quantification for the early diagnosis of perinatal human immunodeficiency virus 1 (HIV-1) infection[J]. An Esp Pediatr 1998,49 : 60-- 64.
  • 10de Mendoza C, Koppelman M, Montes B, et ah Muhicenter eval- uation of the NucliSens EasyQ HIV-1 vl. 1 assay for the quantita- tive detection of HIV-I RNA in plasma[J]. J Virol Methods 2005,127:54--59.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部