摘要
分析了非线性响应特性和发射功率波动对散射测量的联合效应,以及单独的散射测量在这种联合效应作用下产生误差的原因。推导建立了这种联合效应的定标方法的数学模型。利用散射辐射组合系统,构建了一种散射辐射融合测量方法用于实现这一定标方法。数值模拟了该融合测量方法相对于单独的散射测量方法在数据准确度、测量动态范围等性能上的改进效果。
The joint effect of nonlinear response characteristics and transmitting power fluctuation on scattering measurement is analyzed. This joint effect may produce rather large error for scattering measurement alone, and the reason is discussed in detail. To eliminate the error, a mathematic model of calibration is established. Then, a fusion method of scattering and radiometric measurement is developed based on a scatterometer and radiometer combined system. Simulation result reveals improvement in data accuracy and expansion of measurement range by the fusion method.
出处
《电波科学学报》
EI
CSCD
北大核心
2007年第3期442-447,共6页
Chinese Journal of Radio Science
基金
上海市教委自然科学基金资助项目(03AK53)
上海市重点学科基金资助项目(T0102)
关键词
散射测量
辐射测量
多传感器融合
非线性
功率波动
scattering measurement, radiometric measurement, multi-sensor fusion, nonlinearity, power fluctuation