期刊文献+

旋转数字减影血管造影在颅内动脉瘤中的应用价值

下载PDF
导出
摘要 目的:评价旋转DSA在颅内动脉瘤诊断中的应用价值。方法:对62例拟诊颅内动脉瘤病例行常规DSA和旋转DSA检查,通过分析颅内动脉瘤的位置、大小、形态、数目的显示情况对其结果进行对比分析。结果:62例中,经RDSA检出52例57个动脉瘤,与常规DSA相比,RDSA能更准确地显示动脉瘤形态、瘤颈及其与载瘤动脉的关系,对微小或复杂动脉瘤的诊断亦明显优于常规DSA。结论:RDSA能更好地显示颅内动脉瘤,能够更清晰地显示动脉瘤的形态、大小、位置、瘤颈及其与载瘤动脉的关系,提高颅内动脉瘤诊断的准确性。
出处 《温州医学院学报》 CAS 2007年第4期402-403,共2页 Journal of Wenzhou Medical College
  • 相关文献

参考文献11

  • 1Dover Z,Misra M,Thornton J,et al.Guglielmi detachable coiling for intracranial aneurysms:The story so far[J].Arch Neurol,2001,58(2):559-564.
  • 2Sugahara T,Korogi Y,Nakashima K,et al.Comparison of 2D and 3D digial subtraction angiography in evaluation of intracranial aneurysms[J].Am J Neuroradiol,2002,23(9):1545-1552.
  • 3Piotin M,Gailloud P,Bidaut L,et al.CT angiography,MR angiography and rotational digital subtraction angiography for volumetric assessmeng of intracranial aneurysms.An experimengal study[J].Neuroradiology,2003,45(6):404-409.
  • 4张学昕,孙立军,徐朝霞.旋转DSA的临床应用[J].实用放射学杂志,2002,18(10):842-844. 被引量:13
  • 5戴伟英,靳松,崔世民,张蕾莉,刘梅丽,闫世鑫,高满.颅内静脉窦栓塞的CT、MRI、DSA诊断[J].中国医学影像技术,2002,18(3):218-219. 被引量:8
  • 6Okahara M,Kiyosue H,Yamashita,M,et al.Diagnostic accuracy ofmagnetic resonance angiography forcerebral aneurysms in correlation with 3D-digital subtractionangiographic images:A study of 133 aneurysms[J].Stroke,2002,33(7):1803-1805.
  • 7Unno N,Mitsuoka H,Takei Y,et al.Virtual angioscopy using 3-dimensional rotational digital subtraction angiography for endovascular assessment[J].J Endovasc Ther,2002,9(4):529-534.
  • 8杨华,刘健,韩国强,孙业忠,刘窗溪,陈益民,高方友,周石,宋杰,马宁,唐家强,许红,吴晓萍.三维数字减影血管造影在脑血管病诊断和介入治疗中的价值[J].中华医学杂志,2002,82(10):661-664. 被引量:39
  • 9张晓龙,凌锋,沈天真,黄祥龙,王大明,张鸿祺,缪中荣,宋庆斌.三维DSA与二维DSA在颅内动脉瘤诊断中价值的比较[J].介入放射学杂志,2001,10(2):67-71. 被引量:27
  • 10徐力扬,李京雨,张强,刘明,陈华.旋转DSA及三维重建技术在脑血管造影中的应用[J].中国医学影像技术,2003,19(10):1377-1379. 被引量:30

二级参考文献33

  • 1黄庆,李铁林,段传志,汪求精,尹方明,方兵,赵庆平,郭元星.前交通动脉瘤微弹簧圈栓塞治疗效果研究[J].中华神经医学杂志,2004,3(5):350-352. 被引量:9
  • 2李京生,关树森,王忠诚,赵继宗.131例自发性脑内出血的临床分析[J].中华神经外科杂志,1994,10(5):281-283. 被引量:27
  • 3[1]Fahig R, Holdsworth DW, Fox AJ. Characterization of a C-arm mounted XRⅡ for 3D image reconstruction during interventional neuroradiology. Proc SPIE, 1996,2708:351-360.
  • 4[2]Tu RK, Cohen WA, Maravilla KR, et al. Digital subtraction rotational angio-graphy for aneurysms of the intracranial anterior circulation: injection method and optimization. AJNR, 1996,17:1127-1136.
  • 5[3]Fahrig R, Fox AJ, Lownie S, et al. Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results. AJNR,1997,18:1507-1514.
  • 6[4]Heautot JF, Chabert E, Gandon Y, et al. Analysis of cerebrovascular diseases by a new 3-dimentional computerised X-ray angiography system, Neuroradiology, 1998,40:203-209.
  • 7[5]Anxionnat R, Bracard S, Macho J, et al. 3D angiography-clinical interest, first applications in interventional neuroradiology. J Neuroradiol,1998,25:251-262.
  • 8[6]Tantivatana J, Kim SJ, Chavali RV, et al. 3D angiography in evaluation of intracranial aneurysm and arteriovenous malformation (abstract). Intervent Neuroradiol,1999,5(suppl 1):80.
  • 9[7]Moret J, Weill A, Piotin M, et al. Why 3D angiography has become mandatory for treatment of intracranial berry aneurysm? Analysis and results over 100 aneurysms (abstract). Intervent Neuroradiol,1995,5(suppl 1):64.
  • 10Okahara M,Kiyosue H, Yamashita M,et al. Diagnostic accuracy of magnetic resonance angiography for cerebral aneurysms in correlation with 3D-digital subtraction angiographic images: A study of 133 aneurysms[J]. Stroke, 2002, 33(7):1803-1808.