摘要
本文探讨了如何利用有限元方法模拟分析轴压比对预应力混凝土扁梁框架内节点抗震性能影响的方法,并通过3个不同轴压比的预应力混凝土扁梁框架内节点试件的低周反复荷载加载试验进行验证。
Using FEA analysis program,this paper simulates the whole collapse process of inner joints of prestressed concrete flat beam under monotone loading test to research the influence of the axial force ratio to the seismic performance.By the way,the pseudo-static test of three inner joints of prestressed concrete flat beam frame was carried out to compare with the results of the FEA analysis.
出处
《福建建设科技》
2007年第4期26-27,共2页
Fujian Construction Science & Technology
关键词
预应力混凝土
扁梁框架内节点
非线性有限元
抗震性能
轴压比
prestressed concrete
inner joints of flat beam
nonlinear finite element
seismic behavior
the axial force ratio