摘要
设计并实验了300mm×300mm口径的辉光放电室,利用钮扣阴极和自动预电离条形阴极进行实验,获得了大面积均匀的辉光放电。测量了不同状态下辉光放电的放电延时及等离子电阻。
We have constructed and tested aglow discharge chamber with a clear aperture of 300 mm×300mm.By using the“buttons”cathode and the automatic preionization cathode,we have got uniform glow discharge in large area.We have measured delay time of the glow discharge and the plasma resistance under various conditions.So the optimal conditions forming uniform glow discharge in large area were discovered.
出处
《强激光与粒子束》
EI
CAS
CSCD
北大核心
1997年第2期271-276,共6页
High Power Laser and Particle Beams
基金
国家863激光技术领域资助