摘要 In this paper,two new concepts—“main out-of-step mode” and “minor out-of-step mode”—are proposed for power system reliability analysis. Large-scale power system studies found that out-of-step generator groups may have characteristics of the main out-of-step mode and the minor out-of-step mode. The generator groups with main out-of-step modes can determine the out-of-step interface of the large-scale power system,while generators with the minor out-of-step modes cannot play such a role. Therefore,the method of capturing the out-of-step interface by seeking the lowest voltage point(the out-of-step center) can only group the generators with the main out-of-step modes,and may fail to combine the generators with the minor out-of-step modes into proper coherent generator groups. Thus,it is necessary in engineering applications to equip the generators that are likely to have the characteristics of the minor out-of-step modes with separation devices based on off-line simulation studies in order to reduce the risk of further accidents caused by these generators after system separation. In this paper,two new concepts—“main out-of-step mode” and “minor out-of-step mode”—are proposed for power system reliability analysis. Large-scale power system studies found that out-of-step generator groups may have characteristics of the main out-of-step mode and the minor out-of-step mode. The generator groups with main out-of-step modes can determine the out-of-step interface of the large-scale power system,while generators with the minor out-of-step modes cannot play such a role. Therefore,the method of capturing the out-of-step interface by seeking the lowest voltage point(the out-of-step center) can only group the generators with the main out-of-step modes,and may fail to combine the generators with the minor out-of-step modes into proper coherent generator groups. Thus,it is necessary in engineering applications to equip the generators that are likely to have the characteristics of the minor out-of-step modes with separation devices based on off-line simulation studies in order to reduce the risk of further accidents caused by these generators after system separation.
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第8期1340-1345,共6页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 Project (No. 50277034) supported by the National Natural ScienceFoundation of China
关键词 大规模电力系统 异步发电机 异步模式 分离装置 Out-of-step center, Out-of-step interface, Separation device, Main out-of-step mode, Minor out-of-step mode
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部