期刊文献+

CT引导下同轴技术肌肉骨骼肿瘤穿刺活检的临床应用

The Clinical Application of CT-guided Muscleorskeleton Tumor Puncture Biopsy with The Co-axle Technique
下载PDF
导出
摘要 目的:评价应用同轴活检技术,进行CT引导下肌肉骨骼肿瘤穿刺活检的临床应用价值。方法:CT引导下同轴技术穿刺活检肌肉骨骼肿瘤26例,同轴套管针于穿刺点按预定角度、深度快速穿刺,针尖至肿瘤边缘内或近穿刺点1/3处,经同轴套管针置入自动活检针,适度改变同轴套管针方向,不同角度、深度对肿瘤进行切割,取材,固定后行病理学检查。结果:26例患者穿刺成功率100%,病理检查明确诊断率92.3%(24/26),无一例严重并发症。结论:CT引导下同轴技术肌肉骨骼肿瘤穿刺活检,可多次、多点取材,提高阳性率以及正确诊断率,降低并发症发生率,此项技术简便易行,是一种安全、有效的诊断措施。 Objective To evaluate the clinical application value ofCT-guided muscleorskeleton tumor puncture biopsy with the co-axle transfixion pin biopsy technique. Methods The clinical data of 26 cases of CT-guided muscleorskeleton tumor puncture biopsy with the co-axle transfixion pin biopsy technique. Under the prepared angle and depth puncture quickly in the puncture point using the co-axle casing needle. When the needle reached the edge of tumor or the near 1/3 the puncture point. Implant the automatic biopsy needle through the co-axle casing needle. Moderate change the direction of the co-axle casing needle and making different angle and depth dissection and fast cytological examination of the sample . Results The success rate of the puncture about the 26 cases were 100% . The accuracy and false negative rate of the puncture biopsy were 92.3%(24/26) . The produced rate of the complication after puncture were 0% (0/26) .Conclusion CT-guided muscleorskeleton tumor puncture biopsy with the co-axle technique , can selected many times and points . Improved the positive rate and the accuracy rate, reduced the produced rate of the complication. It is a easy technique. It is a safer and efficacious diagnose measure.
出处 《实用医技杂志》 2007年第19期2539-2540,共2页 Journal of Practical Medical Techniques
关键词 CT引导 同轴技术 肌肉骨骼肿瘤 穿刺活检术 CT-guided The co-axle technique Muscleorskeleton tumor Puncture biopsy
  • 相关文献

参考文献4

二级参考文献8

  • 1张雪哲,古晓泉,宋.CT导引下肌肉骨胳活检[J].中华放射学杂志,1994,28(1):43-45. 被引量:21
  • 2[1]Leffler SG,Chew FS.CT-guided percutaneous biopsy of sclerotic bone leions:diagnostic yield and accuracy[J].AJR,1999,172(5):1389-1392.
  • 3[2]Logan PM,Connell DG,Munk PL,et al.Image-guided percutaneous biopsy of musculoskeletal tumors:an algorithm for selection of specific biopsy techniques[J].AJR,1996,166(1):137-141.
  • 4[3]Westcott JL,Rao N,Colley DP.Transthoracic needle biopsy of small pulmonary nodules[J].Radiology,1997,202(1):97-103.
  • 5[4]Li H,Bioselle PM,Shepard JO,et al.Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung:comparison of small and large pulmonary nodules[J].AJR,1996,187(1):105-109.
  • 6[5]Lee HM,Lu DS,Farahauik,et al.Biopies of hepatic done lesions:semi-real-time coronal MR guidance technique[J].Radiology,1996,201(2):496-499.
  • 7[6]Langen HU,Kugel H,Krahe T,et al.Precision of MR-guided needle placement:experimental results[J].Radiology,1996,201(2):358-360.
  • 8张雪哲.全面开展介入性放射技术[J]中华放射学杂志,1994(05).