摘要 利用ICP-MS法对饮用水中的多种元素进行全定量分析,结果表明,ICP-MS法可同时测定饮用水中的多种元素;快速,一个样品仅需3~5分钟;灵敏度和准确度高;精密度好,相对标准偏差一般小于3%;检出限低,达到ng/L-ug/L级;线性范围宽,达到8~9个数量级。 The quantitative analysis of metals in drinking water by ICP - MS, many kinds of metals can be analyzed in drinking water at the same time. It takes about 3 - 5 minutes for every sample. The sensitivity and accuracy are high. The precision is very good, commonly, RSD is below 3%. The detection limit is lower, ng/1 -ng/L. The liner range is wide, 8 -9 grades.
作者 李春颖
出处 《环境科学与管理》 CAS 2007年第7期144-146,共3页 Environmental Science and Management
关键词 ICP-MS 测定 饮用水 金属元素 ICP - MS detection drinking water metals
  • 相关文献

参考文献3

  • 1[1]Agilent 7500 ICP-MS ChemStation Operator's Mannual,2000,1.
  • 2[2]Agilent 7500 ICP-MS Application Handbook,2000,1.
  • 3[3]Method 200.8,Determination of Trace Elements In Waters And Wastes By Inductively Coupled Plasma-Mass Spectrometry,United States Environmental Protection Agency,1999,10.