期刊文献+

年轻者与年老者对毛果芸香碱缩瞳反应的比较

The Contrast of Pupil Constrict Response to the Pilocarpine Between the Young and the Old
下载PDF
导出
摘要 目的观察毛果芸香碱脂质体及滴眼剂对年轻者和年老者的缩瞳反应,明确年轻者与年老者对毛果芸香碱缩瞳反应的异同点。方法利用sonyF717红外线数码相机记录黑暗环境下滴用1%毛果芸香碱脂质体和1%毛果芸香碱滴眼液前后年轻者和年老者瞳孔的动态变化,再传送至电脑,应用imagetool软件来测量,Sigamastat软件统计分析。结果黑暗环境下,年轻者瞳孔平均直径6.8±0.643mm,年老者平均4.4±0.447mm。T检验t=16.1,P<0.0001。1%毛果芸香碱脂质体滴眼后最强缩瞳效果时年轻者瞳孔直径平均为3.6±0.828mm,年老者平均为2.31±0.340mm;T检验t=6.86,P<0.0001。1%毛果芸香碱滴眼液滴眼后最强缩瞳效果时年轻者瞳孔直径平均为4.03±0.816mm,年老者平均为2.35±0.264mm;T检验t=4.95,P=0.0005;年轻者1%毛果芸香碱脂质体缩瞳幅度平均为3.43±0.604mm,年老者1%毛果芸香碱脂质体缩瞳幅度平均为2.28±0.307mm;T检验t=8.07,P<0.0001;年轻者1%毛果芸香碱滴眼液缩瞳幅度平均为3.08±0.556mm,年老者1%毛果芸香碱滴眼液缩瞳幅度平均为2.15±0.194mm;T检验t=3.89,P=0.0025;年轻者与年老者对于毛果芸香碱缩瞳起效时间及持续时间、达最大缩瞳强度时间和缩瞳速率在统计学上无显著差别。结论年轻者瞳孔大于年老者,但年轻者、年老者对毛果芸香碱的缩瞳反应在统计学上无差别。 Objective Observe the pupil constrict response to the pilocarpin,identify the difference of the response between the young and the old. Methods Use the infrared digital camera of sonyF717 to record the dynamic variety of the pupil constrict response to the 1% pilocarpine liposome and the pilocarpine liquid in dark environment. Then deliver the data to the computer, measure the data by imagetool software, analysis the data by the Sigamastat software. Results In darkness,the pupil diameter of the young is equally 6.8 ± 0. 643 mm,the old is equally 4.4 ± 0. 447mm. T test t = 16.1 ,P 〈 0. 0001 o The 1% pilocarpine liposome can constrict the pupil to a minimum diameter of equally 3.6 ± 0. 828 mm in the young, and equally 2. 31 ± 0. 340mm in the old. T test t = 6.86,P 〈 0. 0001. Though, The 1% pilocarpine liquid can constrict the pupil to a minimum diameter of equally 4.03 ± 0. 816 mm in the young, and equally 2. 35 ± 0. 264mm in the old. T test t = 4.95 ,P = 0. 0005 ; The pupil constricting range tol % pilocarpine liposome is equally 3.43 ± 0. 604mm in the young, equally 2.28 ± 0. 307mm in the old. T test t = 8.07,P 〈 0. 0001 ;The pupil constricting range to 1% pilocarpine liquid is equally 3.08 ± 0. 556mm in the young, equally 2.15 ± 0. 194 in the old. T test t = 3.89,P = 0. 0025 ;In statistics there is no deference between the young and the old in pupil initial constricting time, keep constricting time, max constricting time and constricting velocity. Conclusions Young' s pupil diameter is bigger than senior' s, but in statistics ,there is no deference in pupil constricting effect to pilocarpine between the young and the old.
出处 《医学研究杂志》 2007年第8期63-65,共3页 Journal of Medical Research
基金 杭州市医药卫生局科技计划青年基金项目(项目编号:2003Q001)
关键词 毛果芸香碱 脂质体 滴眼液 瞳孔测量 红外线数码相机 Pilocarpine Liposome Eye liquid Pupilmeter Infrared digital camera
  • 相关文献

参考文献5

二级参考文献24

  • 1Victoroff J, Mack WJ, Lyress SA, et al. Muhicenter clinicopathological correlation in dementia[J]. Am J Psychiatry, 1995, 152(10):1476.
  • 2Scinto LF, Daffner KR, Dressier D, et al. A potential noninvasive neurobiological test for Alzheimer's disease[J]. Science, 1994, 266(5187): 1051.
  • 3Loupe DN, Newman NJ, Green RC, et al. Pupillary response to tropicamide in patients with Alzheimer disease[J]. Ophthalmology,1996, 103(3): 495.
  • 4Arai H, Terajima M, Nakagawa T, et al. Pupil dilatation assay by tropieamide in modulated by apolipoprotein E e4 allele dosage in Alzheimer's disease[J]. Neuro Report, 1996, 7(4): 918.
  • 5Molsa PK, Paljarvi L, Rinne JO, et al. Validity of clinical diagnosis in dementia: a prospective clinicopathological study[J]. J Neurol Neurosurg Psychiatry, 1985, 48(11): 1085.
  • 6O'Brart DPS,Corbett MC,Lohmann CP,et al.The effects of ablation diameter on the outcome of excimer laser photorefractive keratectomy; a prospective,randomized,double-blind study.Arch Ophthalmol,1995,113:438~443.
  • 7Krumeich JH,Daniel J,Gast R.Closed-system technique for implantation of iris-supported negative-power intraocular lens.J Refractive Surg,1996,12:334~340.
  • 8Winn B,Whitaker D,Elliott DB,Phillips NJ.Factor affecting light-adapted pupil size in normal human subjects.Invest Ophthalmol Vis Sci,1993,95:1132~ 1136.
  • 9Wachler BS,Krueger RR.Agreement and repeatability of pupillometry using videokeratography and infrared devices.J Refract Surg,2000,26:35~ 40.
  • 10Colvard M.Preoperative measurement of scotopic pupil dilation using an office pupillometer.J Cataract Refract Surg,1999,24:1594~ 1597.

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部