摘要
利用掺杂铒元素荧光光纤的试验样品实验测试了荧光寿命的温度特性,并得到荧光寿命在不同温度下的应变响应关系.试验表明,荧光寿命会随着温度的升高而降低;与温度相比荧光寿命随应变的变化很小.提出了一个潜在的同时测量应变和温度的传感器模型.
An experiment system has been established. Some samples are produced to measured the fluorescence lifetime of temperature characteristic and get the relationship between strain and temperature versus the fluorescence lifetime at the same time. The experiment result was fitted and analyzed. The test results show that the fluorescence lifetime decreased with the increasing of temperature. The change of fluorescence lifetime with the strain is inconspicuous comparing to that with the temperature.
出处
《光子学报》
EI
CAS
CSCD
北大核心
2007年第7期1281-1284,共4页
Acta Photonica Sinica
基金
黑龙江省自然科学基金(A0308)资助
关键词
荧光光纤
荧光寿命
同时测量
温度
应变
fluorescence lifetime
fluorescence fiber
simultaneous measurement
temperature.