摘要
分析了钢筋混凝土结构中受力主筋保护层的作用,针对现场施工中存在的问题,结合具体工程,阐述了保护层厚度不符合要求将对结构承载能力产生的影响,提出了施工中加强钢筋保护层质量控制的措施。
It analyzes the effect of main forcing protecting layer in steel concrete structure. According to problems in constructing court and combined with practical project, it elaborates the substandard thickness of protecting layer will cause effect to structural capacity, and brings forward some quality controlling measures of strengthening steel concrete protecting layer in construction.
出处
《山西建筑》
2007年第23期221-223,共3页
Shanxi Architecture
关键词
混凝土结构
钢筋保护层
质量控制
concrete structure, steel concrete protecting layer, quality control