摘要
以浙江杭州某工厂改造用房地基防腐蚀处理工程为背景,在理论计算分析的基础上对该工程的浅基础、桩基础以及地基的防腐蚀处理进行了论述,水质分析结果表明,地下水由原来的中等腐蚀变为弱腐蚀,达到了预期的加固效果。
Through the reinforcement construction of a workshop foundation acid erosion in Zhejiang, the erosion treatments of the shallow foundation, pills and ground are discussed based on the theory analysis. The water analysis result shows that the ground water become weak erosion from the original middle erosion, and the treatment achieves the desired effect.