期刊文献+

Rapid Determination of Dopamine and Its Metabolites During in vivo Cerebral Microdialysis by Routine High Performance Liquid Chromatography With Electrochemical Detection 被引量:1

Rapid Determination of Dopamine and Its Metabolites During in vivo Cerebral Microdialysis by Routine High Performance Liquid Chromatography With Electrochemical Detection
下载PDF
导出
摘要 Objective To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection.Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 μL/min.A reverse phase HPLC with electrochemistry was used to assay DA,DOPAC,and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats.In order to identify the reliability of this method,its selectivity,linear range,precision and accuracy were tested and the contents of DA,DOPAC,and HVA in rat microdialysates were determined.Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 μmol/L for DOPAC(r2= 0.9996),from 66 nmol/L to 1.3 μmol/L for DA(r2=1.0000)and from 69 nmol/L to 1.4 μmol/L for HVA(r2=0.9992).The recovery of DOPAC(0.30,0.77,1.49 μmol/L),DA(0.26,0.69,1.32 μmol/L),and HVA(0.27,0.71,1.37 μmol/L)was 82.00±1.70%,104.00±4.00%,98.70±3.10%;92.30±1.50%,105.30±2.30%,108.00±2.00%;80.00±7.80%,107.69±8.00%,and 108.66±3.10%,respectively at each concentration.Their intra-day RSD was 3.3%,3.4%,and 2.5%,and inter-day RSD was 4.2%,2.3%,and 5.6%,respectively.The mean extracellular concentrations of DOPAC,DA,and HVA in rat brain microdialysates were 10.7,2.4,and 9.2 μmol/L(n=6),respectively.Conclusion The findings of our study suggested that the simple,accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats. To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.
出处 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第4期317-320,共4页 生物医学与环境科学(英文版)
基金 This work was supported by the National Natural Science Foundation of China (Grant No. 30560171).
关键词 多巴胺 DOPAC 代谢物 色谱法 Dopamine (DA) 3,4-dihydroxyphenylacetic acid (DOPAC) Homovanillic acid (HVA) Cerebral microdialysis High performance liquid chromatography Electrochemical detection
  • 相关文献

参考文献8

  • 1M C Kurth,C H Adler (1998).COMT inhibition:a new treatment strategy for Parkinson's disease.Neurology.50 (suppl5),3-14.
  • 2A T Wood,M R Hall (2000).Reversed-phase high-performance liquid chromatography of catecholamines and indoleamines using a simple gradient solvent system and native fluorescence detection.J,Chromatagr B Biomed Sci Appl 744,221-225.
  • 3Takashi Yoshitake,Shimako Yoshitake,Kaoru Fujino.(2004).High-sensitive liquid chromatographic method for determination of neuronal release of serotonin,noradrenaline and dopamine monitored by microdialysis in the rat prefrontal cortex.J neurosci meth 140,163-168.
  • 4K Takezawa,M Tsunoda,K,Murayama (2000).Automatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.Analyst.125,293-296.
  • 5S,Xiong,H,Han,R,Zhao,et al.(2001).Capillary electrophoresis of catecholamines with laser-induced fluorescence intensified charge-coupled device detection.Biomed Chromatogr 15,83-88.
  • 6Fang Xu,Mengnan Gao,Guoyue Shi,et al.(2001).Simultaneous detection of monoamines in rat striatal microdialysis at poly(para-aminobenzoic acid) modified electrode by high-performance liquid chromatography.Analytica Chimica Acta,439,239-246.
  • 7Wen Zhang,Xuni Cao,Yunfeng Xie,et al.(2003).Simultaneous determination of the monoamine neurotransmitters and glucose in rat brain by microdialysis sampling coupled with liquid chromatography-dual electrochemical detector.J Chromatogr,B 785,327-336.
  • 8Laszlo Virag,Robert A,Whittington.(2002).Highly sensitive chromatographic assay for dopamine determination during in vivo cerebral microdialysis in the rat.J Chromatogr B 772,267-272.

同被引文献3

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部