期刊文献+

应用电子散斑干涉术对单端固定桥的受载分析 被引量:1

Analysis on Force Distribution of a Posterior Cantilever Fixed, Partial Denture by means of Electronic Speckle Pattern Interferometry
下载PDF
导出
摘要 本文目的是对单端固定桥的运动及其受力状态进行试验性研究。采用电子散斑干涉术这一新的光学技术分别对下颌单端固定桥修复前后进行4种垂直加载测试,观察实时显示的散斑干涉条纹图,并测量相应牙槽骨处的离面位移。据此分析了单端固定桥修复前后,相应牙槽骨的位移变化及其规律,加载条件的改变对该位移变化的影响,从而为临床上设计单端固定桥提供了生物力学的参考。 For the first time, Electronic Speckle Pattern Interferometry was introduced in this study. The purpose of this study was to analyze the force distribution on the surface of the supporting bone of the abutment teeth with a mandibular posterior cantilever fixed partial denture. By means of Electronic Speckle Pattern Interferometry, four kinds of vertical loadings were exerted on the mandibular teeth before and after a posterior cantilever fixed partial denture treatment respectively. The real-time Electronic Speckle Interference Pattern was recorded photographically and the corresponding out of plane displacement of the supporting bone was measured. The change of this out of plane displacement of the supporting bone and the effect of loadings on it were analyzed. The results showed that a posterior cantilever fixed partial denture contributed to transmiss the stress and after a posterior cantilever fixed partial denture treatment, the out of plane displacement of supporting bone decreased significanlty. This study, provided a biomechanical reference for a cantilever fixed partial denture design.
出处 《上海生物医学工程》 1997年第1期26-29,共4页 Shanghai Journal of Biomedical Engineering
关键词 单端固定桥 电子散斑干涉术 离面位移 牙槽骨 Cantilever fixed partial denture Electronic Speckle Pattern Interferometry Out of plane displacement
  • 相关文献

参考文献1

  • 1朱希涛,白沁,周辛庚,章玮宝,刘春阳.完全固定桥与半固定桥受力状况的激光全息分析[J]中国生物医学工程学报,1985(01).

同被引文献12

  • 1曾艳,王嘉德.下颌第一恒磨牙三维有限元模型的建立及应力分析[J].中华口腔医学杂志,2005,40(5):394-397. 被引量:15
  • 2Owens SE,Buschang PH,Cope JB,et al.Experimental evaluation of tooth movement in the beagle dog with the mini-screw implant for orthodontic anchorage[].American Journal of Orthodontics and Dentofacial Orthopedics.2007
  • 3Ma J,Zhang W,Wang L,et al.Stability and bone response of im-mediately loaded micro-implants in beagle dogs[].International Journal of Oral and Maxillofacial Surgery.2008
  • 4Coelho PG,Freire JN,Granato R,etal.Bone mineral apposition rates atearly implantation times around differently prepared titanium surfaces: astudy in beagle dogs[].International Journal of Oral and Maxillofacial Surgery.2011
  • 5Weinberg LA.The biomechanics of force distribution in implant-supported prostheses[].International Journal of Oral and Maxillofacial Implants.1993
  • 6Wang CH,Lee HE,Wang CC,et al.Methods to im-prove a periodontally involved terminal abutment of acantilever fixed partial denture a finite element stressanalysis[].Journal of Oral Rehabilitation.1998
  • 7AWADALLA H A,AZARBAL M,ISMAIL Y H,et al.Three-dimensional finite element stress analysis of a cantileverfixed partial denture[].The Journal of ProsThetic Dentistry.1992
  • 8Manda M,Galanis C,Georgiopoulos V,et al.Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support;a three-dimensional finite element analysis[].The Journal of ProsThetic Dentistry.2010
  • 9Laurell L,Lundgren D.Distribution of occlusal forces along unilateral posterior two-unit cantilever segments in cross-arch fixed partial dentures[].The Journal of ProsThetic Dentistry.1988
  • 10ErasLan O,Sevimay M,Usumez A, et al.Effects of cantilever design and material on stress distribution in fixed partial dentures--a finite element analysis[].Journal ofOralRehabilitation.2005

引证文献1