摘要 目的:应用动态浊度法定量检测痰热清注射液中的细菌内毒素。方法:采用中国药典2005年版附录细菌内毒素定量检测法。结果:将痰热清注射液进行1∶80稀释,可排除干扰,回收率在50%-200%,无干扰作用。结论:应用动态浊度法测定痰热清注射液中的细菌内毒素是可行的。 Objective: To establish a determination of endotoxin in Tanreqing Injection by turbidimetric kinetic assay. Methods: Inhibition or enhancement test for bacterial endotoxins test were used according to Chinese Pharmacopoeia 2005. Results: 1:80 solution of Tanreqing injection showed no interference on test and the recovery was 50% - 200%. Conclusions: Bacterial endotoxin test for Tanreqing injection by turbidimetric kinetic assay has been established.
作者 林颖 陈华龙
出处 《儿科药学杂志》 CAS 2007年第4期51-52,共2页 Journal of Pediatric Pharmacy
关键词 动态浊度法 痰热清注射液 细菌内毒素 干扰实验 Turbidimetric kinetic assay Tanreqing injection Bacterial endotoxin Interfering test