摘要 根据国家对建筑能耗节能50%和节材的要求,目前在夏热冬冷地区对建筑围护结构普遍采用空心砌块以满足对热阻的要求。应用热流计法对内插保温层空心砌块的热阻进行了实验研究,分析了砌块的热工性能,找出该空心砌块存在的不足,并分别着眼于砌块外部结构和内部构造提出了改进方法,使砌体能够满足夏热冬冷地区对建筑围护结构节能的要求。 According to the request of energy saving 50% of building energy consumption and material saving by our country, for the moment, hollow building blocks are widely used in building exterior-protected constructions to satisfy the request of thermal resistance in hot summer and cold winter area. In this paper, through experiment research with heat-flow meter method on the thermal resistance of a certain hollow building block with inserting thermal insulation layer, the thermal characteristics of the building block are analyzed, the deficiency of hollow building block is found out, the improvement methods are put forward respectively with a view to exterior and interior structures, which make the masonry envelope satisfy the demands on the energy saving of building exterior-protected constructions in hot summer and cold winter area.
机构地区 南京工业大学
出处 《新型建筑材料》 北大核心 2007年第8期77-80,共4页 New Building Materials
基金 2006年南京市墙体改革办公室资助项目
关键词 节能 围护结构 热阻 热流密度 空心砌块 energy saving exterior-protected construction thermal resistance heat flow density hollow building block
  • 相关文献

参考文献2

  • 1Das,Subodh K.Study of Exterior Facades-Problems and Solutions[C].Application and Performance of Structural Materials and Exterior Facades.Proceedings of 2 Sessions in Conjunction with the ASCE Convention.1986:92-114.
  • 2栾伟,何嘉鹏,杜垲.节能墙体空心砌块热阻特性的研究[J].南京工业大学学报(自然科学版),2003,25(5):33-36. 被引量:15

二级参考文献4

共引文献14

同被引文献18

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部