期刊文献+

北京大学1MeV RFQ加速器性能优化研究

Optimization Study of the 1MeV RFQ at Peking University
原文传递
导出
摘要 在入口归一化均方根发射度为0.05mm·mrad时,北京大学1MeV射频四极场加速器ISR-1000束流传输效率为97%.当更换新的ECR源时发射度增加到0.2mm·mrad,此时束流传输效率下降为89%.在不改变腔体结构的前提下,对入口参数及极间电压进行了优化调整,将效率提高到98%.还进行了ISR-1000对入射束流参数的敏感性分析,给出了各参数允许的变化范围. ISR-1000 will be used as the injector of the SFRFQ, which is under development at Peking University. The possibility to improve its transmission has been investigated. In order to get better transmission, the input beam parameters and the vane voltage have been optimized without changing the structure of the RFQ. In addition, the error study on input beam parameters of ISRol000 has been carried out. The sensitivity of those parameters has been obtained by simulation.
出处 《高能物理与核物理》 CSCD 北大核心 2007年第8期783-786,共4页 High Energy Physics and Nuclear Physics
基金 国家自然科学基金(10455001 10605003)资助~~
关键词 整体分离环 射频四极场 匹配 均温 integral split ring, RFQ, matching, equipartition
  • 相关文献

参考文献8

  • 1Kapchinskij I M,Tepiyakov V A.Prib.Tech.Eksp.,1970,4:19
  • 2陈佳洱,方家驯,李纬国,潘欧嘉,陆元荣,李德山,袁敬琳,王丽珊,曾葆青.重离子整体分离环高频四极场(RFQ)加速结构的研究[J].自然科学进展(国家重点实验室通讯),1994,4(3):271-277. 被引量:5
  • 3CHEN Jia-Er,FANG Jia-Xun,YU Jin-Xiang et aL.Progress of RFQ for Ion Implantation at Peking University.In:Proc.of EPAC2000.Vienna,Austria,2000.1850-1852
  • 4LU Yuan-Rong,CHEN Jia-Er,FANG Jia-Xan et al.NIM,2003,A515:394-401
  • 5YAN Xue-Qing,CHEN Jia-Er,FANG Jia-Xun et al.NIM,2005,A539(3):606
  • 6Reiser M.Theory and Design of Charged Particle Beams.New York:John Wiley & Sons,1994
  • 7Jameson R A.AIP Conf.Prof.,1992,279:969
  • 8Jameson R A.IEEE Trans.Nucl.Sci.,1981,NS-28:2408

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部