摘要
西门子SIREMOBIL2000移动式小C形臂高压采用逆变技术和闭环调节,直接采用墙电,高压和毫安输出准确,适合用于骨科手术。本文简述了该机的工作原理,列举了两例故障排除。
Siemens SIREMOBIL 2000 type C arm DSA with inverted and closed circuit technologies applied in high voltage circuit can use outlet on the wall. Its output of high voltage and mA is accurate and it is suitable for Osteooperation. This paper describes briefly the working principle and two cases of troubleshooting for Siremobil 2000 C type arm.
出处
《医疗设备信息》
2007年第7期111-111,91,共2页
Information of Medical Equipment