摘要
从办公建筑的热舒适出发,说明了改善窗际热环境的必要性。指出除通过建筑构造来改善环境外,空调分内外区是常用的手法,但会带来能量混合损失。介绍了一些可以不设外区空调系统而又能改善窗际热环境的空调措施。
Starting with the thermal comfort conditions in office buildings, explains the necessity of improving the window side thermal environment(WSTE), points out that the common practice of dividing the air conditioned space into perimeter and inner zones tends to engender mixing loss of energy. Describes ways adopted in Japan of improving window side thermal environment with much simpler or even without the systems for perimeter zone air conditioning.
出处
《暖通空调》
北大核心
1997年第2期18-25,共8页
Heating Ventilating & Air Conditioning
关键词
窗际热环境
空气屏障
空调系统
办公楼
节能
thermal comfort conditions, window side thermal environment, inner zone, perimeter zone, mixing loss of energy, air flow window, air barrier