摘要
介绍了电压跌落对钢铁企业生产的影响,对动态电压补偿器的工作原理和过程做了介绍,并通过应用实例说明了动态电压补偿器的使用效果。
The effect of voltage dropping on production of iron and steel was presented. The work principle and procedure of a dynamic voltage compensator were described. Usage effect of the compensator was expounded by an example.
出处
《冶金动力》
2007年第4期10-12,共3页
Metallurgical Power
关键词
敏感负荷
电压跌落
动态电压补偿器
sensitive load
voltage dropping
dynamic voltage compensator