期刊文献+

Feasibility of photoacoustic tomography for ophthalmology 被引量:3

Feasibility of photoacoustic tomography for ophthalmology
原文传递
导出
摘要 For the eyeball composed of membrane and liquid, the contrast of ultrasound imaging is not high due to its small variance in acoustic impedance. As a new imaging modality, photoacoustic tomography combines the advantages of pure optical and ultrasonic imaging together and can provide high resolution, high contrast images. In this paper, the feasibility of photoacoustic tomography for ophthalmology is studied experimentally. A Q-switched Nd:YAG pulsed laser with 7-ns pulse width is used to generate photoacoustic signal of a porcine eyeball in vitro. The two-dimensional (2D) optical absorption image of the entire eyeball is reconstructed by time-domain spherical back projection algorithm. The imaging results agree well with the histological structure of the eyeball and show a high imaging contrast. For the eyeball composed of membrane and liquid, the contrast of ultrasound imaging is not high due to its small variance in acoustic impedance. As a new imaging modality, photoacoustic tomography combines the advantages of pure optical and ultrasonic imaging together and can provide high resolution, high contrast images. In this paper, the feasibility of photoacoustic tomography for ophthalmology is studied experimentally. A Q-switched Nd:YAG pulsed laser with 7-ns pulse width is used to generate photoacoustic signal of a porcine eyeball in vitro. The two-dimensional (2D) optical absorption image of the entire eyeball is reconstructed by time-domain spherical back projection algorithm. The imaging results agree well with the histological structure of the eyeball and show a high imaging contrast.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第8期475-476,共2页 中国光学快报(英文版)
关键词 Acoustic impedance Algorithms Laser pulses Light absorption OPHTHALMOLOGY Photoacoustic effect Q switched lasers Two dimensional Ultrasonic imaging Acoustic impedance Algorithms Laser pulses Light absorption Ophthalmology Photoacoustic effect Q switched lasers Two dimensional Ultrasonic imaging
  • 相关文献

参考文献10

  • 1L.V.Wang. Disease Markers . 2004
  • 2R.A.Kruger,K.Stantz,and W.L.Kiser Jr. Proceedings of SPIE the International Society for Optical Engineering . 2002
  • 3Y.Zeng,D.Xing,Y.Wang,B.Yin,and Q Chen. Optics Letters . 2004
  • 4Y.Su,F.Zhang,K.Xu,J.Yao,and R.K.Wang. Journal of Physics D Applied Physics . 2005
  • 5A.A.Karabutov,E.V.Savateeva,N.B.Podymova,and A.A.Oraevsky. Journal of Applied Physics . 2000
  • 6U.Oberheide,B.Jansen,I.Bruder,H.Lubatschowski,H.Welling,and W.Ertmer. Proceedings of SPIE the International Society for Optical Engineering . 2001
  • 7M.Xu,Y.Xu,and L.V.Wang. IEEE Transactions on Biomedical Engineering . 2003
  • 8V.G.Andreev,A.A.Karabutov,and A.A.Oraevsky. IEEE Trans.Ultrasonics,Ferroelectrics and Frequency Control . 2003
  • 9M.Xu,and L.V.Wang. IEEE Transactions on Medical Imaging . 2002
  • 10R.A.Kruger,W.L.Kiser,Jr,K.D.Miller,H.E. Reynolds,D.R.Reinecke,G.A.Kruger,and P.J.Ho- racker. Proceedings of SPIE the International Society for Optical Engineering . 2000