期刊文献+

CGMS与CSⅡ泵联合在初发2型糖尿病中治疗意义 被引量:2

下载PDF
导出
摘要 采用自身前、后对照,对16例初发的2型糖尿病予胰岛素泵输注控制血糖,同时使用CGMS评估。结果:与治疗前相比明显降低(P<0.01);血糖漂移的幅度明显降低。结论:CGMS与CSⅡ联合应用能更有效的血糖控制。
出处 《实用糖尿病杂志》 2007年第4期40-41,共2页 Journal of Practical Diabetology
  • 相关文献

参考文献4

  • 1UKprospectivediabectes study group.Lancet 1998; 352:837-853.
  • 2陈爱荣,何继瑞,宁英远,倪安民.糖尿病病人动态血糖监测临床应用研究进展[J].国外医学(内分泌学分册),2004,24(B05):46-48. 被引量:69
  • 3Muggeo M,Verlato G,Bonora E,et al.Long-term instabitity of fasting plasma glucose,anovel predictor of cardiovascular mortality in elderly patients with non-insulin-dependent diabetes mellitus:the Verona diabetes study.Circulation 1997;96:1750-1754.
  • 4Risso A,Mercuri F,Quagliaro L,et al.Intermittent high glucose enhances apoptosis in human umbilical vein endothelial cells in culture.Am J Physiol Endocrinol Metab 2001;281:E924-E930.

二级参考文献14

  • 1Vering T,Adam S,Drewer H,et al.Wearable microdialysis system for continuous in vivo monitoring of glucose.Analyst,1998,123: 1605-1609.
  • 2Cheyne EH,Cavan DA,Kerr D.Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers.Diabetes Technol Ther,2002,4: 607-613.
  • 3Gross TM,Bode BW,Einhorn D,et al.Performance evaluation of MiniMed continuous glucose monitoring system during patient home use.Diabetes Technol Ther,2000,2:49-56.
  • 4Caplin NJ,O' Leary P,Bulsara M,et al.Subcutaneous glucose sensor values closely parrallel blood glucose during insulin-induced hypoglycaemia.Diabet Med,2003,20: 238-241.
  • 5Guerci B,Floriot M ,Bohme P,et al.Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs.Diabetes Care,2003,26: 582-589.
  • 6Boland E,Monsod T,Delucia M,et al.Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes.Diabetes Care,2001,24:1858-1862.
  • 7Chico A,Vidal-Rios P,Subira M,et al.The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabo
  • 8Kessler L,Passemard R,Oberholzer J,et al.Reduction of blood glucose variability in type 1 diabetic patients treated by pancreatic islet transplantation: interest of continuous glucose monitoring.Diabetes Care,2002,25: 2256-2262.
  • 9Lourido J,Ederoth P,Sundvall N,et al.Correlation between blood glucose concentration and glucose concentration in subcutaneous adipose tissue evaluated with microdialysis during intensive care.Scand J Clin Lab Invest,2002,62: 285-292.
  • 10Tiessen RG,Rhemrev-Boom MM,Korf J,et al.Glucose gradient differences in subcutaneous tissue of healthy volunteers assessed with ultroslow-microdialysis and a nanolitre glucose sensor.Life Sci,2002,70:2457-2466.

共引文献68

同被引文献28

引证文献2

二级引证文献6