期刊文献+

火焰原子吸收光谱法测定铝合金中铬 被引量:2

FAAS Determination of Chromium in Aluminum Alloy
下载PDF
导出
摘要 铝合金样品溶于盐酸及过氧化氢中,其铬量用火焰原子吸收光谱法测定。采用空气-乙炔富燃火焰原子化并用锶盐作干扰抑制剂。铬的工作曲线浓度范围为1.2~20.0 mg.L-1(r=0.999)。方法应用于4个铝合金标样的测定,所得结果与标准值相符。方法的RSD(n=5)值在2.1%~4.2%之间,回收率在97%~104%之间。 Sample was dissolved in hydrochloric acid and hydrogen peroxide, and its chromium content was determined by FAAS. Reductive flame of air-acetylene gas mixture was used in the atomization, and strontium salt was used as inhibitor. Conditions for chemical treatment of sample and operation of the instrument were studied and optimized. Working curve in range of 1.2 mg to 20.0 rng of chromium( Ⅲ ) per L of test solution was prepared, having the correlation coefficient of 0. 999. In its application to the analysis of 4 standard samples, results obtained were in consistency with the standard values. Values of RSDrs (n=5) and of recovery were found in the ranges of 2. 1%-4. 2% and 97%-104% respectively.
作者 姚波
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2007年第8期673-674,共2页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 火焰原子吸收光谱法 铬(Ⅲ) 铝合金 Flame atomic absorption spectrometry Chromium Aluminum alloy
  • 相关文献

参考文献3

  • 1张士林.简明铝合金手册[M].上海:科学技术文献出版社,2002.14.
  • 2邓勃.原子吸收分光光度法[M].北京清华大学出版社,1982..
  • 3威尔茨 B.原子吸收光谱法[M].北京:海洋出版社,1980.

共引文献9

同被引文献345

引证文献2

二级引证文献2