摘要 目的 观察2%匹鲁卡品诱导不同设计的单焦点人工晶状体(Intraocular Lens,IOL)光学面的移动,探讨伪凋节(pseudoaccommodation)产生的机制。方法 收集43例IOL眼患者,应用移近法测量其调节幅度,使用前段光学相干断层扫描仪(Anterior Chamber Optical Coherence Tomography,ACOCT)测量患眼最佳远视力矫正下和2%匹鲁卡品诱导状态下前房深度的变化。结果 移近法测量的SA60AT、MA6CBM和AKreos三种IOL平均调节幅度分别为1.98±0.64D,2.07±58D,2.15±0.54D,差异无统计学意义。ACOCT测量的最佳远视力矫正和2%匹鲁卡品诱导两种状态下SA60AT、MA60BM和Akreos三种IOL平均前移幅度分别为(0.35±0.25)mm(t=6.25p=0.00),(-0.02±0.04)mm(t=-1.55p=0.12),(0.28±0.10)mm(t=8.37 p=0.00)。三种IOL调节幅度与药物诱导下的IOL移动幅度不相关(r=0.087,0.337,0.428p=0.722,0.342,0.218)。结论 药物诱导下板状襻(Akreos)和一片式(SA60AT)设计的IOL光学面可以发生前移,三片式(MA60BM)设计的IOL光学面没有前移。 Objective Observe the intraocular lens movement,measured as a change in anterior chamber depth (ACD) induced by 2% pilocarpine,to study the mechanism of pseudoaccommodation. Methods 43 eyes with monofocal intraocular lens were included,push-up method was used to measure accommodative amplitude. The ACD and pupil diameter were measured using anterior chamber optical coherence tomography when eyes in the conditions of the best corrected distance vision acuity and conditions under 2% pilocarpine.Results The mean accommodative amplitude measured by push-up method of SA60AT, MA60BM, Akreos IOL were 1.98 ± 0.64D, 2.07 ±0.58 D, 2.16 ± 0.54 D, SA60AT IOL(one piece)and Akreos IOL(plate-haptic)showed a forward movement (SA60AT IOL 0.35±0.25mm, Akreos IOL 0.28±0.10mm); MA60BM IOL(3-piece)showed no change m ACD. In each group, there Was no correlation between Accommodative amplitude and IOL movement amplitude induced by 2% pilocarpine(r=0.087, 0.337, 0.428 p=0.722, 0.342, 0.218). Conclusion One piece IOL and plate-haptic IOLcan move forward induced by 2% pilocarpine. But 3-piece IOL showed no change in ACD.
出处 《中国实用眼科杂志》 CSCD 北大核心 2007年第8期826-828,共3页 Chinese Journal of Practical Ophthalmology
关键词 伪调节 晶状体 人工 Pseudoaccommodation, Intraocular Lens
  • 相关文献

参考文献12

  • 1杨亚波,姚克,姜节凯,王竞,吴燮灿.单焦后房型人工晶体眼的调节[J].中华眼科杂志,1996,32(2):98-100. 被引量:28
  • 2Sugtani Y, Komori R,Katoch R,et al.Apparent accommodation (pseudoaccommodation)on pseudophakia.Folia ophthahnol Jpn, 1979,30(3):326
  • 3Jean M,Liliana W, Leonardo W, et al .Pseudoaccommodation: BioComFold versus a foldable Silicone intraocular lens.J cataract Refract Surg 1999;25:262-267.
  • 4Radhakrishman S,Rollins AM,Roth JE,et al.Real-time optical coherence tomography of anterior segment at 1310.Arch Ophthalmol. 2001,119:1179-1185.
  • 5俞阿勇,赵云娥,金婉卿,诸葛晶,许琛琛.白内障超声乳化术后假晶状体眼的调节灵活度[J].中国实用眼科杂志,2006,24(3):267-269. 被引量:4
  • 6Muftuoalu O Hosal BM,Karel F,et al.Drug-induced intraocular lens movement and near visual after AcrySof intraocular lens implantation. J cataract Refract Surg 2005;31 (7): 1298-1305
  • 7杨亚波,姚克,姜节凯,吴奕灿.视标法、动态检影法、P-VEP法对人工晶体眼的调节测定比较[J].中国实用眼科杂志,1995,13(10):595-597. 被引量:6
  • 8Kohnen T, Thomala MC,Cichocki M,et al. Internal anterior chamber diameter using optical coherence tomography compared with White-to-white distances using automated measurements.J cataract Refract Surg'2006;32(11): 1809-1813
  • 9Muller M,Dahmen G,Porksen E,et al. Anterior chamber angle measurement with optical coherence tomography:intraobserver and interobserver variability. J cataract Refract Surg 2006;32(11): 1803- 1808
  • 10Cumming J,Kammann J. Experience with an accommodation IOL. J cataract Refract Surg 1996;22:1001

二级参考文献24

  • 1杨亚波,姚克,姜节凯,王竞,吴燮灿.单焦后房型人工晶体眼的调节[J].中华眼科杂志,1996,32(2):98-100. 被引量:28
  • 2施明光,温州医学院学报,1990年,20卷,233页
  • 3瞿佳,1990年
  • 4徐广弟,眼屈光学,1987年
  • 5段昌敏,中华眼科杂志,1985年,21卷,216页
  • 6吴星路,眼科研究,1984年,2卷,209页
  • 7Sugitani Y,Komori T,Katoh R,et al.Apparent accommodation (pseudoaccommodation) on pseudophakia.Floia Ophthalmol Jpn,1979,30:326.
  • 8Garca A,Cacho P,Lara F,et al.The relation between accommodative facility and general binocular dysfunction.Ophthal.Physiol.Opt,2000,20(2):98-104.
  • 9Sterner B,Abrahamsson M,Sjostrom A.The effects of accommodative facility training on a group of children with impaired relative accommodation-a comparison be tween dioptric treatment and sham treatment.Ophthal.Physiol.Opt,2001,21(6):470-476.
  • 10Rouse MW,Deland PN,Mozayani S,et al.Binocular accommodative facility testing reliability.Optom Vis Sci,1992,69:314-319.

共引文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部