摘要
The biological aerated filter(BAF)was used to treat the oil-field produced water.The removal effi- ciency for oil,COD,BOD and suspended solids(SS)was 76.3%—80.3%,31.6%—57.9%,86.3%—96.3%and 76.4%—82.7%,respectively when the hydraulic loading rates varied from 0.6m.h- 1to 1.4m.h -1.The greatest part of removal,for example more than 80%of COD removal,occurred on the top 100cm of the media in BAF.The ki- netic performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loading rates in biological aerated filters could be described by cr/ci=1-exp(-2.44/L 0.59).This equation could be used to predict the BOD removal efficiency at different hydraulic loading rates.
The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, respectively when the hydraulic loading rates varied from 016m·h^-1 to 1.4m·h^-1. The greatest partof removal, for example more than 80% of COD removal, occurred on the top 100cm of the media in BAF. The kinetic .performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loadingrates, in biological aerated filters could be described by c1/c1=l-exp(-2.44/L^0.59). This equation could be used topredict the B OD.removal efficiency at different hydraulic loading rates.
基金
Supported by the National Natural Science Foundation of China (No.59978020).
关键词
生物学充气绿色片
动力学
废水处理
油田水制造
biological aerated filter, kinetics, oil field produced water, wastewater treatment