摘要
The paper addresses the system performance of coal-fired power unit with changed auxiliary system or other local heat disturbance. The idea of state space model is imported and the universal formula for the calculation of system performance output is deduced on the system state equation. Two important vector of system are worked out under linear system assumption and transform. The transfer matrix is the characteristics of system itself and is constant for a similar condition, which greatly facilitates the analysis. The concept of thermal disturbance vector is proposed to construct the thermal disturbance input easily. The method can be helpful for analyzing any thermal disturbance input satisfying the assumption and also for supplementing the correction means of performance test. An example of 600MW power unit is presented to demonstrate its availability.