摘要 目的:探讨GE HAWKEYE仪器实施脑SPECT灌注显像与CT同机图像融合以及质量控制方法。材料和方法:制作脑SPECT显像的平板头托及其Y轴偏移检测。改变采集模式,手动调节双探头到最小旋转半径,对点源模型及患者进行SPECT/CT采集,以及SPECT/CT同机图像融合处理及其质量控制分析。结果:调整头托及采集技术后,在HAWKEYE仪器实施脑SPECT/CT同机图像融合显像。使用改良头托后,模型及患者进行SPECT/CT显像,能够准确实施同机SPECT/CT图像融合。结论:通过技术改进,可以在GE HAWKEYE仪器上实施脑SPECT/CT同机显像以及准确的图像融合。 Purpose: To study the technique of the image fusion in hybrid SPECT/CT device in cerebral imaging and the method of quality control. Materials and Methods: A planar head holder was modified, and the rotate center and its deviation in Y and Z axis were examined. The acquisition method was modified to adjust manually rotated radius first, and SPECT/ CT acquisition was performed in a model with radiopharmaceutical and patients. The images were fused and its quality control was examined and analysed. Results:Cerebral imaging in this hybride SPECT/CT can be performed on the modified planar head holder. The rotated center between SPECT and CT was consistent. Excursion of the fusion image in Y and Z axis was no more than two millimeter between SPECT and CT imaging in model. The SPECT images were accurately fused with CT images. The fusion image of cerebral SPECT/ CT in patients was satisfied.Conclusion: After modified the head holder and imaging method, we can do the SPECT/ CT imaging in brain and fulfill its image fusion.
出处 《中国医学计算机成像杂志》 CSCD 2007年第4期292-295,共4页 Chinese Computed Medical Imaging
关键词 仪器 脑灌注显像 图像融合 Cerebral imaging Image fusion Quality control
  • 相关文献

参考文献8

  • 1王荣福,杨熊飞,张春丽,付占立,范岩,张旭初,徐文怀.符合线路SPECT在消化系统肿瘤术后复发转移中的应用研究[J].中国医学计算机成像杂志,2004,10(2):124-128. 被引量:4
  • 2Pfannenberg AC, Eschmann SM, Horger M, et al. Benefit of anatomical - functional image fusion in the diagnostic work - up of neuroendocrine neoplasms. Eur J Nucl Med Mol Imag, 2003, 30: 835 - 843.
  • 3Townsend DW, Cherry SR. Combining anatomy and function: the path to true image fusion. Eur Radiol, 2001,11: 1857- 858.
  • 4卢健,胡志忠,杨如乃.医学图像融合技术的研究[J].上海生物医学工程,2006,27(3):163-167. 被引量:14
  • 5Nomayr A, Romer W, Strobel D, et al. Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun, 2006,27:521 - 528.
  • 6O'Connor MK, Kemp BJ. Single- photon emission computed tomography/ computed tomography: basic instrumentation and innovations. Semin Nucl Me(t, 2006, 36:258 - 266.
  • 7Ingui C J, Shah NP, Oates ME. Endocrine neoplasm scintigraphy: added value of fusing SPECT/ CT images compared with traditional side- by - side analysis. Clin Nucl Med, 2006, 31:665- 672.
  • 8Kovacevic N, Lobaugh N J, Bronskill M J, et al. Aro- bust method for extraction and automatic segmentation of brain images. Neuroimage, 2002, 17: 1087- 1010.

二级参考文献22

  • 1李卫华,周军,周连文,程英蕾.一种基于提升小波分解图像融合方法[J].计算机应用,2006,26(2):403-405. 被引量:9
  • 2王荣福.肿瘤:^(18)F-DG PET代谢显像[J].国外医学(放射医学核医学分册),1997,21(3):106-110. 被引量:13
  • 3Bloch.I,Maitre.H,Data fusion in 2D and 3D image processing:an overview Computer Graphics and ImagProcessing,1997,Proceedings,Brazilian,On page(s):127-134
  • 4Pohl L.C.,Multisensor image fusion in remote sensing:concept,methords and application[J].Intenational Jounal of Remote Sensing,1998,19(5):823-854
  • 5Brown L G.A survey of image registration techniques.ACM Computing Surveys.1991,24(4):326-376
  • 6Burt.P.J.,Adelson E.H.,The Laplacian Pyramid as a Compact Image Code,IEEE Trans.On Communication,1983,31(4):532-540
  • 7Toet.A,Image fusion by a ratio of low-pass pyramid,Pattern Recognition Letters,1989,9(4):255-261
  • 8Toet.A,L.J.van.Ruyven,J.M.Valeton,Merging thermal and visual images by a contrast pyramid,Optical Engineering,1989,7(28):789-792
  • 9Tort.A morphological pyramid image decomposition.Pattern Recognition Lett.1989,9(4):255-261
  • 10Burt PJ,A gradient pyramid basis for patten-selective image fusion,in Proc.Of the Society for Information Display conference.San Jose,USA:SID Press,1992,Vol.16:467-470

共引文献16

同被引文献15

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部