期刊文献+

混凝土渗透系数与交流电导相关性的试验研究 被引量:3

Water permeability coefficient and alternating current conductivity of concrete
下载PDF
导出
摘要 在高性能混凝土的渗透性和耐久性研究中,利用电化学理论对其进行快速评定是目前较常用的一种方法,而传统的透水试验方法则难以实施.用交流电导法和透水法测定了水泥砂浆试块的渗透性并研究了这两种试验方法所得结果的相关性.结果表明,经试块粉末浸液化学成分修正后的交流电导值与渗透系数有较好的相关性;用交流电测量普通混凝土的电导并以此反映混凝土的渗透性是可行的. In the study of the permeability and durability of high performance concrete, a normal technique has been found to determine the permeability of concrete through electrochemical theory rapidly since the traditional pervious test is difficult to carry on. Permeability of ordinary concrete is determined by pervious test and electricity method in this paper, and the relativity of the results of the two methods is researched. The results show that there is an ideal correlation between the water permeability coefficient and the conduction of the concrete modified by the pore chemicals. It is feasible to determine permeability of ordinary concrete by measuring electric conduction of the concrete by alternating current.
出处 《青岛理工大学学报》 CAS 2007年第4期14-18,共5页 Journal of Qingdao University of Technology
基金 山东省自然科学基金重点项目(Z2006F02)
关键词 混凝土 渗透性 交流电导 渗透系数 孔溶液 concrete permeability alternating current conductivity water permeability coefficient pore solution
  • 相关文献

参考文献7

  • 1范宏,赵铁军,田砾.氯离子标准扩散计算模型用于寿命预测分析[J].青岛理工大学学报,2006,27(2):18-23. 被引量:6
  • 2田砾,孙雪飞,范宏,赵铁军.高性能混凝土检测鉴定中应注意的几个问题[J].青岛建筑工程学院学报,2005,26(4):17-20. 被引量:8
  • 3AASHTO Designation. T277-83,Standard Method of Test for Rapid Determination of the Chloride Permeability of Concrete[S].
  • 4ASTM C1202-91 ,Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration[S].
  • 5Feldman R F, Chan G W, Brousseau R J, et al. Investigation of the Rapid Chloride Permeability Test[J]. ACI Materials Journal, 1994, 91(2) :246-255.
  • 6Tong L, Gjorv O E. Chloride Diffusivity based on Migration Testing[J]. Cement and Concrete Research, 2001, 31:973-982.
  • 7Salem Th M, Ragai Sh M. Electrical Conductivity of Granulated Slag Cement Kiln Dust-Silica Fume Pastes at Different Porosities[J].Cement and Concrete Research, 2001, 31:781-787.

二级参考文献19

  • 1刘志勇,孙伟,杨鼎宜,周新刚.基于氯离子渗透的海工混凝土寿命预测模型进展[J].工业建筑,2004,34(6):61-64. 被引量:26
  • 2中国工程院士木水利与建筑学部工程结构安全性与耐久性研究咨询项目组.混凝土结构耐久性设计与施工指南[M].北京:中国建筑工业出版社,2004..
  • 3李秋义 朱亚光 田砾.钻芯法检测混凝土强度的尺寸效应[A].见:赵铁军主编.高强与高性能混凝土及其应用[C].北京:中国建材工业出版社,2004.51-58.
  • 4范宏 赵铁军.氯离子环境下混凝土结构寿命预测[J].青岛建筑工程学院学报,2004,25:1-2.
  • 5Chatterji S. On the application of Fick's Second Law to chloride migration through Portland cement concrete. Cement and Concrete Research, 1995, 25:299-303.
  • 6Siemes T, Polder R, de Vries H. Design of concrete structures for durability. Heron, 1998, 43(4): 227-244.
  • 7Tuuti K. Crossion of steel in concrete. CBI Forskning Research. Swedish cement and concrete research institute. Institute of Technology. Stockholm, 1982.
  • 8Bamforth P. Definition of exposure classes for chloride contaminated environments. In: Page C L, Pbamforth, Figg J W. eds. Proceedings of the Fourth SCI Conference on Corrosion of Reinforcement in Concrete Construction. Cambridge: RSC for SCI, 1996. 176-190.
  • 9Helland S. Assessment and prediction of service life of marine structures. In: Siemes T, Meyer H. eds. Design of Durability of Concrete. Berlin, 1999. 64-75.
  • 10Berke N, Hicks M. Predicting chloride profiles in concrete. Proceedings of National Association of Corrosion Engineers Annual Conference. Houston,1993. 341/1-341/15.