摘要
对抗震区住宅采用泵送混凝土全现浇结构的常见裂缝类型进行总结,分别从设计、施工、温度影响、使用商品混凝土等方面分析其产生原因,并制定相应对策。
The common cracks appeared and cracks' mason is analysed in some in full cast - in - situ pumping concrete structure are summarized in this paper aspects of design, construction, temperature influence and useage of premixed conerete. The relating countermeasure is also compiled.
出处
《江苏建筑》
2007年第4期72-73,78,共3页
Jiangsu Construction
关键词
现浇板裂缝
原因分析
防治对策
cracks in cast - in - situ
reason analysis
protective countermeasure