期刊文献+

300MW循环流化床锅炉翻床现象及处理方法 被引量:11

BED-OVERTURN PHENOMENON OF UNDERPANTS LEG IN 300 MW CFB BOILER AND REMEDIAL METHOD THEREOF
下载PDF
导出
摘要 分析了白马循环流化床(CFB)示范电站有限公司300 MW CFB锅炉翻床的原因,提出了一次风流量和一次风压力自动调节的控制方案。一次风系统投入自动运行后,两侧双支腿床压之差基本能控制在2.5 kPa,有效避免了锅炉翻床现象的发生。 The causes resulting in bed -overturn of 300 MW circulating fluidized bed (CFB) boiler in Baima CFB Demonstration Power Plant Co Ltd have been analysed, a control scheme of automatic regulation for primary air flow rate and for primary air pressure being put forward. After putting the primary air system into automatic operation, the pressure difference between two underpants legs can be basically controlled to 2.5 kPa, avoiding effectively the occurence of bed- overturn phenomenon in CFB boiler.
出处 《热力发电》 CAS 北大核心 2007年第8期55-57,共3页 Thermal Power Generation
基金 四川白马引进技术300MW循环流化床示范工程(发改委发改投资2003250)
关键词 CFB锅炉 两支腿 翻床 一次风系统 自动控制 CFB boiler underpants leg bed- overturn primary air system automatic control
  • 相关文献

参考文献4

二级参考文献12

共引文献12

同被引文献97

引证文献11

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部