摘要 残留在空调通风管道中的气溶胶粒子被气流带入房间会降低室内空气品质,影响人体健康。为了改善空调通风系统的卫生状况,国内外的许多学者分别采用物理实验、经验公式、数值模拟等方法研究了气溶胶粒子在管道中的沉积规律,本文详细综述了这部分内容,并对三种方法作出了比较。最后指出今后该领域的研究和发展方向。 The aerosol particles deposited onto duct surfaces will be taken into rooms by supply air, which would pollute the indoor environment and cause adverse effects on human health. Many authors investigate particle deposition in ducts by means of Physical Experiment, Empiricism and Numerical Simulation. These contents are summarized and above three methods are compared in this paper. At last it also indicates the subse- quent study and development orientation in this field.
作者 来苏 邹钺
出处 《洁净与空调技术》 2007年第3期1-6,13,共7页 Contamination Control & Air-Conditioning Technology
关键词 气溶胶粒子 通风管道 物理实验 数值模拟 Aerosol particles Ventilation ducts Physical experiment Numerical simulation
  • 相关文献

参考文献34

  • 1Wargocki, P., Wyon, D.P., Sundell, J., Clausen, G. and Fanger, P.O. (2000) The effects of outdoor air supply rate in an office on perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity. Indoor Air, 10: 222-236.
  • 2Q Ouyang, HJ Li, W Dai, XC Chen and YX Zhu (2005) .The differences and connections between dynamic characteristics of natural and mechanical wind in built environment. Indoor Air.
  • 3朱颖心,欧阳沁,戴威.建筑环境气流紊动特性研究综述[J].清华大学学报(自然科学版),2004,44(12):1622-1625. 被引量:11
  • 4Wood, N.B. (1981) A simple method for the calculation of turbulent deposition to smooth and rough surfaces. Journal of Aerosol Science, 12: 275-290.
  • 5Friedlander, S.K. and Johnstone, H.F. (1957) Deposition of suspended particles from turbulent gas streams. Industrial and Engineering Chemistry, 49:1151-1156.
  • 6Postma, A.K. and Schwendiman, L.C. (1960) Studies in micrometrics: I. Particle deposition in conduits as a source of error in aerosol sampling. Report HW-65308, Richland, Washington: Hanford Laboratory
  • 7Schmel, G.A. (1968) Aerosol deposition from turbulent airstreams in vertical conduits. Report BNWL-578, Richland, Washington: Pacific Northwest Laboratory.
  • 8李念平,张丽薇,付峥嵘,朱青松.气溶胶颗粒在风管系统中沉降的实验研究[J].建筑热能通风空调,2006,25(6):8-10. 被引量:4
  • 9Liu, B.Y.H. and Agarwal, J.K. (1974) Experimental observation of aerosol deposition in turbulent flow. Aerosol Science, 5: 145-155.
  • 10El-Shobokshy, M.S. (1983) Experimental measurements of aerosol deposition to smooth and rough surfaces. Atmospheric Environment, 17: 639-644.

二级参考文献57

  • 1韩海涛,张天伟,张吉光.空调系统对室内空气品质的影响[J].制冷与空调(四川),2004,18(3):64-68. 被引量:6
  • 2赵彬,陈玖玖,李先庭,陈曦.室内颗粒物的来源、健康效应及分布运动研究进展[J].环境与健康杂志,2005,22(1):65-68. 被引量:43
  • 3徐文华.空调风系统的清洗[J].清洗世界,2005,21(2):21-27. 被引量:7
  • 4Busch J F.Tale of two populations: Thermal comfort in air- conditioned and naturally ventilated offices in Thailand [J].Energy and Buildings,1992,18(3/4): 235-249.
  • 5Ealiwa M A,Taki A H,Howarth A T,et al.An investigation into thermal comfort in the summer season of Ghadames,Libya [J].Building and Environment,2001,36(2): 231-237.
  • 6Fanger P O,Melikov A K,Hanzawa H,et al.Air turbulence and sensation of draught [J].Energy and Building,1988,12: 21-39.
  • 7Barbara G,Christa K,Ulrike G.The significance of air velocity and turbulence intensity for responses to horizontal rafts in a constant air temperature of 23 ℃ [J].Inter J Indu Ergonomics,2000,26(6): 639-649.
  • 8Mayer E.Physical causes for draft: Some new findings [J].ASHRAE Trans,1987,93(1): 540-548.
  • 9XIA Yizai,NIU Jianlei,ZHAO Rongyi.Effects of turbulent air on human thermal sensations in a warm isothermal environment [J].Int J Indoor Air Quality and Climate,2000,10(4): 289-296.
  • 10Fanger P O,Pedersen C J K.Discomfort due to air velocities in spaces[A].Proc of Meeting of Commission B1,B2,E1 of Int Instit Refig [C].Beograd,1977,4: 289-296.

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部