摘要
采用改进的电压和电流测试方法对衬底电极外加不同电压Vs的射频等离子体中的阻抗和功率消耗进行了测试分析.结果表明:在射频电极施加恒定的电压Vel时,随衬底电极外加电压Vs的增加,辉光的电流在增加,结果导致阻抗在减小;另外,通过计算分析发现:仅有一小部分功率用于辉光,大部分功率消耗在匹配器和电缆上.通过对等离子体电学特性的综合测试分析也说明:在保证有足够多的硅烷时,衬底电极外加电压Vs增加时将会提高薄膜的沉积速率.
Plasma impedance and power consumption were measured by modified voltage-current method at different applied voltages on the substrate electrode. The results indicated that discharge current increases with the increase of applied voltage on the substrate electrode when the applied voltage of RF electrode is fixed. As a result, plasma impedance decreases. In addition, only a small part of power was used by the plasma and a large part of power was consumed on the matching network and cables. Through the analysis of plasma electrical properties, it was found that the deposition rate of thin films will be increased with the increase of applied voltage on the substrate electrode so long as there is enough silane.
出处
《物理学报》
SCIE
EI
CAS
CSCD
北大核心
2007年第9期5309-5313,共5页
Acta Physica Sinica
基金
国家重点基础研究发展规划(批准号:2006CB202602
2006CB202603)
国家自然科学基金(批准号:60506003)
天津市自然科学基金(批准号:05YFJMJC01600)
南开大学博士启动基金(批准号:J02031)
教育部新世纪人才计划(NCET)
科技部国际合作重点项目(批准号:2006DFA62390)资助的课题.~~
关键词
等离子体
辉光功率
阻抗
诊断
plasma, discharge power, impedance, diagnostic