期刊文献+

流动注射分光光度法测定废水中砷 被引量:5

Flow injection spectrophotometric determination of arsenic in waste water
下载PDF
导出
摘要 建立了测定砷(Ⅲ)的流动注射光度分析法。在0.5mol/L的硫酸介质中,溴酸钾的强氧化性将砷(Ⅲ)氧化成砷(Ⅴ),剩余的溴酸钾与碘化钾反应生成单质碘,利用碘与淀粉形成蓝色络合物,间接测定微量砷㈣。方法的线性范围为0.04~1.20μg/mL,检出限为6.2×10^-3μg/mL(3倍噪音);除IO3,IO4,Cr2O7^2-等强氧化性阴离子外,其余阴离子以及大量常见阳离子对砷的测定没有干扰。对质量浓度为0.30gg/mL的As(Ⅲ)标准溶液连续进样11次测定,相对标准偏差为1.8%。该方法用于废水中砷的测定,加标回收率在98.7%~100.5%之间。 A new flow-injection spectrophotometric method has been developed for the determination of arsenic(Ⅲ). After arsenic(Ⅲ)is oxidized to arsenic(Ⅴ)with strong oxidant like potassium bromate,the excessive potassium bromate in the system oxidizes continually potassium iodide to iodide,which forms a blue complex with starch. The complex can be used for determining arsenic indirectly in 0.5 mol/L sulfuric medium. The linear range for the determination is 0.04-1.20μg/mL,and the detection limit is 6.2 × 10^-3 μg/mL(3σ). Other anions and large amounts of cations do not interfere in the determination of As(Ⅲ)except strong oxygenation properties of anions such as IO3^-,IO4^- and Cr2O7^2-. The relative standard deviation obtained is 1.8% for continual injection of 0.30 μg/mL As(Ⅲ)standard solution (n = 11). The method has been applied to the determination of arsenic(Ⅲ)in waste water, and the relative standard deviation is between 98.7%-100.5%.
出处 《冶金分析》 EI CAS CSCD 北大核心 2007年第8期43-46,共4页 Metallurgical Analysis
基金 国家863项目(2002AA639290)
关键词 流动注射光度分析法 废水 arsenic flow injection spectrophotometry waste water
  • 相关文献

参考文献8

  • 1国家环保局.水和废水监测分析方法:第4版[M].北京:中国环境科学出版社,2002:304-306.
  • 2Yang L L, Zhang D Q. In Situ-preconcentration and Determination of Trace Arsenic in Botanical Samples by Hydride Generation-graphite Furnace Atomic Absorption Spectrometry with Pd-Zr as Chemical Modifier[J]. Anal. Chim. Acta,2003,491:91 -97.
  • 3蔡卓,吴健玲,朱晓韵,李树海,郑向明.催化极谱法快速测定硫磺中微量砷[J].化学世界,2001,42(1):14-16. 被引量:14
  • 4Sbarato V M,Saanchez H J. Analysis of Arsenic Poilution in Groundwater Aquifers by X-ray Fluorescence [J].Applied Radiation and Isotopes, 2001,54: 737 - 740.
  • 5Vassileva E, Hoenig M. Determination of Arsenic in Plant Samples by Inductively Coupled Plasma Atomic Emission Spectrometry with Ultrasonic Nebulization: A Complex Problem[J].Spectrochimica Acta: Part B, 2001,56 : 223-232.
  • 6李冰,史世云,何红蓼,马新荣,温宏利,吕彩芬.电感耦合等离子体质谱法同时测定地质样品中痕量碘溴硒砷的研究 Ⅱ.土壤及沉积物标准物质分析[J].岩矿测试,2001,20(4):241-246. 被引量:47
  • 7范衍琼,林小葵,李玉萍.流动注射氢化物发生原子吸收分光光度法测定水中砷[J].中国卫生检验杂志,2001,11(3):315-315. 被引量:9
  • 8Panayot K P, Ivan S, Trajce S, et al. , Flow injection hydride generation electrothermal atomic absorption spectrometric determination of toxicologically relevant arsenic in urine[J]. Talanta,2006,69:1112-1117.

二级参考文献11

共引文献63

同被引文献70

引证文献5

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部