摘要 本文除对ICP某些参数和光谱性质进行了研究外,还进行了有机溶剂的选择。实验结果表明,在样品溶液中加入30%(V/V)的甲基异丁酮(MIBK),显著地提高了分析线强度和信背比,提高了分析方法的灵敏度。当溶液中Gd<sub>2</sub>O<sub>3</sub>浓度为5mg/ml时,测定下限为钐0.001%,铕0.0004%,铽0.1002%,镝0.0004%,钇0.0002%。其相对标准偏差为2.6—5.3%。 In this paper, some main working parameters of ICP were measured, several organic solvents have been studied using ICP, and the results of effects of concentration of the methyl isobutyl ketone (MIBK), plasma forward power, desolvation temperature and carrier gas flow are given. The sample solution contains 30% (V/V) of MIBK was introduced into the ICP, therefore the determination sensitivities were improved, because the effective uptake rate of solution and the line intensities were increased. For the sample solution containing 5mg/ml of Gd_2O_3, the detection limit is 0.001% for Sm_2O_3, 0.0004% for Eu_2O_3 and Dy_2O_3, 0.002% for Tb_4O_7,0.0002% for Y_2O_3 respectively. The tested accuracies were satisfactory and the relative standard deviations were in the range of 2.6—5.3%.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 1990年第3期44-47,共4页 Spectroscopy and Spectral Analysis
  • 相关文献

参考文献3

  • 1綦文娣,Rare Met,1987年,7卷,1期,59页
  • 2张卓勇,分析化学,1987年,15卷,9期,801页
  • 3袁甫,分析化学,1985年,13卷,4期,306页

同被引文献5

  • 1胡仁坤,周希员,刘光华.P507萃取树脂分离稀土元素时基本参数的测定[J]分析试验室,1986(01).
  • 2彭春霖,崔永德,宋清秀.几种矿物酸为流动相对HEH(EHP)萃取柱色谱分离稀土的影响[J]分析化学,1983(07).
  • 3彭春霖,纪永仪,刘春兰,隋喜云,胡仁坤,吕爱玉.507-HCl体系萃取色谱法分离稀土的研究 Ⅲ.高纯氧化钕中La、Ce、Pr、Sm和Y的化学光谱测定[J]分析化学,1981(03).
  • 4彭春霖,纪永仪,卢安球,刘德成.-HCl体系萃取柱色谱法分离稀土的研究——1.酸度试验[J]分析化学,1980(04).
  • 5张书秀,沈高扬.ICP-AES法直接测定纯氧化钆中十四个稀土杂质[J].中国稀土学报,1991,9(2):170-173. 被引量:4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部