摘要 The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfunction was defined by E'〈A' in pulse-wave tissue Doppler for inter-ventricular septal (IVS) of mitral annulus. In 24 patients with LV diastolic dysfunction, including 12 patients with delayed relaxation (delayed relaxation group) and 12 patients with pseudo-normal function (pseudo-normal group) and 24 normal volunteers (control group), data of full-volume image were acquired by real-time three-dimensional echocardiography and subjected to volume-time curve analysis. EDV (end-diastolic volume), ESV (end-systolic volume), LVEF (left ventricular ejection fraction), PER (peak ejection rate), PFR (peak filling rate) from RT3DE were examined in the three groups. Compared to the control group, PFR (diastolic filling index of RT3DE) was significantly reduced in the delayed relaxation group and pseudo-normal group (P〈0.05). There were no significant differences in EDV, ESV, LVEE PER (P〉0.05). It is concluded that PFR, as a diastolic filling index of RT3DE, can reflect the early diastolic function and serve as a new non-invasive, quick and accurate tool for clinical assessment of LV diastolic function. The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfunction was defined by E'〈A' in pulse-wave tissue Doppler for inter-ventricular septal (IVS) of mitral annulus. In 24 patients with LV diastolic dysfunction, including 12 patients with delayed relaxation (delayed relaxation group) and 12 patients with pseudo-normal function (pseudo-normal group) and 24 normal volunteers (control group), data of full-volume image were acquired by real-time three-dimensional echocardiography and subjected to volume-time curve analysis. EDV (end-diastolic volume), ESV (end-systolic volume), LVEF (left ventricular ejection fraction), PER (peak ejection rate), PFR (peak filling rate) from RT3DE were examined in the three groups. Compared to the control group, PFR (diastolic filling index of RT3DE) was significantly reduced in the delayed relaxation group and pseudo-normal group (P〈0.05). There were no significant differences in EDV, ESV, LVEE PER (P〉0.05). It is concluded that PFR, as a diastolic filling index of RT3DE, can reflect the early diastolic function and serve as a new non-invasive, quick and accurate tool for clinical assessment of LV diastolic function.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第4期475-478,共4页 华中科技大学学报(医学英德文版)
基金 This project was supported by a grant from Guangdong Provincial Natural Sciences Foundation (No 05300738)
关键词 real-time three-dimensional echocardiography left ventricular diastolic function volume-time curve real-time three-dimensional echocardiography left ventricular diastolic function, volume-time curve
  • 相关文献

参考文献2

二级参考文献14

  • 1庄磊,王新房,谢明星,陈立新,费洪文,杨颖,王静,黄润青,陈欧迪,王良玉.经静脉声学造影实时三维超声心动图测量左室心肌重量的实验研究[J].中国医学影像技术,2003,19(5):529-531. 被引量:12
  • 2费洪文,王新房,谢明星,陈立新,庄磊,王静,黄润青,杨颖.实时三维超声心动图测量右室容积的实验研究[J].中国医学影像技术,2003,19(5):532-534. 被引量:22
  • 3Michal Hubka,Edward L. Bolson,John A. McDonald,Roy W. Martin,Brad Munt,Florence H. Sheehan.Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation[J].The International Journal of Cardiac Imaging.2002(2)
  • 4WangXF.Real timethree dimensionalimaging:principleandclinicalapplicationfuture[].BME&ClinMed.2002
  • 5WangXF.Real timethree dimensionalimaging:newbreakthroughinthefieldofultrasonictechnique[].ChinJUltrasonogr.2003
  • 6WangJ,WangXF,XieMX ,etal.Initialstudyofmeasurementmethodologyforrightventricularvolumebyreal timethree dimensionalechocardiography[].ChinJUltrasonogr.2003
  • 7HuangRQ,WangXF,XieMX ,etal.Real timethree dimensionalechocardiographyformeasurementofnormalleftventricularvolumeanditssystolicfunction[].ChinJUltrasonogr.2003
  • 8YangY,WangXF,XieMX ,etal.Real timethree dimensionalechocardiographyinassessmentofleftandrightventricularvolume:methodsstudy[].ChinJUltrasonogr.2003
  • 9FeiHW,WangXF,XieMX ,etal.Validationofreal timethree dimensionalechocardiographyforquantifyingleftventricularvolume:inexperimentalstudy[].ChinJUltrasonogr.2003
  • 10FeiHW,WangXF,XieMX ,etal.Validationofreal timethree dimensionalechocardiographyforquantifyingrightventricularvolume:invitrostudy[].ChinJMIT.2003