期刊文献+

螺旋锥束CT重建Katsevich算法在含噪投影中的应用 被引量:2

Spiral cone-beam CT Katsevich reconstruction algorithm applying in noised projections
下载PDF
导出
摘要 针对含有噪声的投影数据,在利用螺旋锥束Katsevich算法进行重建的过程中,首先采用了一种改进的中值滤波方法对投影体数据进行预处理,然后对处理后的投影数据拟合求导来取代Katsevich算法中的直接求导,减小了噪声带来的负面影响。计算机仿真实验结果证实了这种方法的有效性。 The improved median filter is adopted to pretreat the projections which contain random noise and a Little abnormal noise.Then the derivative of the disposed projections is calculated with a fitting method instead of direct derivative one.This method reduces the negative effect coming from the noise.Computer simulation experiment proves the validity of this method.
出处 《计算机工程与应用》 CSCD 北大核心 2007年第26期187-189,226,共4页 Computer Engineering and Applications
基金 国家自然科学基金( the National Natural Science Foundation of China under Grant No60672098) 重庆市科技公关计划( the KeyTechnologies R&D Program of Chongqing City China under Grant NoCSTC2006AB3027)
关键词 螺旋锥束CT KATSEVICH算法 改进的中值滤波 拟合求导 图像重建 计算机仿真 spiral cone-beam CT Katsevich algorithm improved median filter fitting derivative image reconstruction computer simulation
  • 相关文献

参考文献2

二级参考文献65

  • 1周日峰,张平,张泽宏.高能X射线探测器射线串扰模拟研究[J].核技术,2005,28(12):937-939. 被引量:6
  • 2吴沭新,钱永庚,王经瑾.用MonteCarlo方法模拟设计工业CT探测器[J].核电子学与探测技术,1996,16(5):340-344. 被引量:5
  • 3Ritman,EL,et al.Computed tomographic imaging of the heart the dynamic spatial reconstructor.Radiol,Clin North.Am,1980,18(3):p.547-555.
  • 4Robb,RA,et al.High-speed three-dimensional x-ray computed tomography:The dynamic spatial reconstructor.in Proceedings of the IEEE.1983.
  • 5Ritman,EL.RA.Robb,and LD,Harris,Imaging physiological functions:experience with the DSR 1985:philadelphia;proeger.
  • 6Wang,G.Lin,TH,Cheng PC,Shinozaki DM,Kin,HG:Scanning cone-beam reconstruction algorithms for x-ray microtomography.Proc.SPIC Vol.1556,p.99-112.July.1991(Scanning Microscopy Instrumentation,Gordon S.Kino:Ed).
  • 7Kolender,W.A.Basics and techniques of spiral CT.Radiologe,1999,39(9):p.809-819;quiz 819.
  • 8Wang G.and M.W.Vannier,Longitudinal resolution in volumetric x-ray computerized tomography-analytical comparison between conventional and helical computerized tomography.Med Phys,1994,21(3):p.429-33.
  • 9Taguchi,K,and,H.Aradate,Algorithm for image reconstruction in multi-slice helical CT,Med Phys.,1998,25(4):p.550-561.
  • 10Kachelriess,M,S.Schaller,and W.A.Kalender,Advanced single-slice rebinning in cone-beam spiral CT.Med,Phys.,2000,27(4):p.754-772.

共引文献8

同被引文献16

  • 1Tuy H K.An inversion formula for cone-beam reconstruction[J]. SIAM Journal on Applied Mathematics, 1983,43:546-552.
  • 2Smith B.Image reconstruction from cone-beam projections:Nec- essary and sufficient conditions and reconstruction methods[J]. IEEE Trans Med Imaging, 1985,4: 14-25.
  • 3Katsevich A.Theoretically exact filtered backprojection-type in- version algorithm for Spiral CT[J].SIAM Journal on Applied Mathematics, 2002,62: 2012-2026.
  • 4Katsevich A.Improved exact FBP algorithm for Spiral CT[J]. Adv Appl Math,2004,32:681-697.
  • 5Yu H,Wang G.Studies on implementation of the Katsevich algo- rithm for spiral cone-beam CT[J].Journal of X-ray Science and Technology, 2004,12:97-116.
  • 6Yu H, Wang G.Studies on artifacts of the Katsevich algorithm for spiral cone-beam CT[J].Proceedings of SPIE, 2004, 5535: 540-549.
  • 7Zou Y, Pan X C.Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT[J].Phys Med Biol, 2004,49: 941-959.
  • 8Ye Y, Wang G.Exact FBP CT reconslruction along general scanning curves[J].Med Phys,2005,32:42-48.
  • 9李庆杨,王能超,易大义擞值分析[M].武汉:华中科技大学出版社,2001:103-105.
  • 10KATSEVICH A. An improved exact filtered backprojection algo- rithm for spiral computed tomography[J]. Advances in Applied Mathematics, 2004,32(4):681-697.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...