期刊文献+

大型循环流化床锅炉降低厂用电率措施 被引量:9

Measures to reduce auxiliary power consumption rate for large-scale CFB boilers
下载PDF
导出
摘要 由于调峰频繁,燃用劣质煤或煤矸石的循环流化床锅炉厂用电率一般高达11%~12%。通过对河南义马锦江电厂2台DG440/13.7-Ⅱ2型循环流化床锅炉在煤质、风道、布风板等方面进行深入分析,对冷渣器、其他辅机进行技术改造,并在运行方式、燃烧调整等方面进行优化,使厂用电率降至9%以下,取得了较大的经济效益。 As a result of frequently peaking, the auxiliary power consumption rate for the CFB boiler plants fired with low-quality coal or coal gangue is as high as 11% - 12%. Based on the in-depth analysis on the coal quality, air duet and air ventilation board for the two DG440/ 13.7-Ⅱ2 CFB boilers in Jinjiang Power Plant, the ash cooler and other auxiliary machines were retrofitted, in addition, the operation mode and combustion regulation were optimized. Thus the auxiliary power consumption rate was reduced below 9% obtaining significant economic benefits.
出处 《中国电力》 CSCD 北大核心 2007年第9期65-68,共4页 Electric Power
关键词 循环流化床锅炉 厂用电率 节能 CFB boiler auxiliary power consumption rate energy saving
  • 相关文献

参考文献4

  • 1DG440/13.7-Ⅱ2锅炉说明书[R].东方锅炉(集团)股份有限公司.2003.
  • 2张全胜,田卫东,王宝军,冯美杰.CFB锅炉发电机组的节能技术探讨[J].电力设备,2005,6(6):77-78. 被引量:16
  • 3义马锦江能源综合利用有限公司1号锅炉性能试验报告[R].河南电力试验研究所.2004,
  • 4陈克仁,循环流化床锅炉设计、凋试、运行与检修维护技术实用手册[M].北京:当代中国音像出版社,2003.

二级参考文献2

  • 1[1]火力发电设备技术手册(第一卷).锅炉.北京:机械工业出版社,2000.
  • 2[2]许振茂编著.变频调速装置及其调试、运行与维修.北京:兵器工业出版社,1994.

共引文献15